Sometimes I see wrong Calling-Station-Id in CDRs.
This is a correct CDR:
|2010-03-03
16:14:42|983953495540|123|136|212.119.194.171|212.157.203.68|16|16|162
This is a INcorrect CDR:
|2010-03-03
16:20:40|984957816610|70|188.128.41.94:25528|188.128.41.94|217.150.18.35|16|16|176
GK logs IP address:port instead of Calling-Station-Id.
Here is my CDRString parameter:
CDRString=|%{setup-time}|%{Dialed-Number}|%d|%{Calling-Station-Id}|%{caller-ip}|%{callee-ip}|%c|%{cause-translated}|%n
Thees errors occurs periodically from different originating gateways (Cisco
1760. 2801. 2811).
Is there a way to solve it?
Thank you.
------------------------------------------------------------------------------