[EMAIL PROTECTED] wrote on 08/06/2007 11:54:34
AM:
> Hi,
>
> I tried the OPENHPI_DAT_SAVE="YES", but now each time I restart the
> daemon, previous asserted alarms are seen as new alarms in the DAT:
>
> OpenHPI> dat
> (1) 2007-08-06 11:32:59 MAJOR - SENSOR 27/4097 0x10
> (2) 2007-08-06 11:32:59 MAJOR - SENSOR 27/4097 0x1
> No alarms in DAT.
>
> Became after a restart:
>
> OpenHPI> dat
> (1) 2007-08-06 11:32:59 MAJOR - SENSOR 27/4097 0x10
> (2) 2007-08-06 11:32:59 CRITICAL - SENSOR 0/0 0x0
> (3) 2007-08-06 11:44:23 MAJOR - SENSOR 27/4097 0x10
> (4) 2007-08-06 11:44:23 MAJOR - SENSOR 27/4097 0x1
> No alarms in DAT.
>
> What is alarm 2? Why alarm 3 is now a "duplicate" of alarm 1?
>
I think alarm 2 should be the same as before the restart. 3 and 4 come to
be duplicates because the sensor alarms are being detected during initial
resource discovery (when you restart) and you had already persisted to
disk alarms 1 and 2.
The strange alarm 2 concerns me as it may indicate a bug in the retreival
of alarms from disk on a restart.
--Renier-------------------------------------------------------------------------
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems? Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now >> http://get.splunk.com/