[EMAIL PROTECTED] wrote on 09/14/2007 11:03:11
AM:
> Hi,
>
> I am filling in the ResourceInfo.ManufacturerId field correctly when I
> generate an event during discovery. However hpitree reports it as an
> Unknown Manufacturer. I searched in openhpid and client source for
> switch on this field and didn't find any. Do I need to make a change to
> one of the modules (openhpid or client code) to have it recognize the ID
> correctly.
Yes, the change should be in utils/sahpi_struct_utils.c,
oh_decode_manufacturerid().