Hi,
I am trying to generate event for the "RPT Entry Id-4" and "Sensor RDR Resource
Id-131073". The print of this RPT is given below:
RPTEntry[4] tag: HS DASD 1 2
Entity Path: {SYSTEM_CHASSIS,9}{DISK_DRIVE,2}
RDR[131073]: Sensor[ 1] HS DASD temperature sensor 1 = 125.000
Degrees F
Current Sensor State = UPPER_MINOR
Ranges::
Nominal of Range: 100.000 Degrees F
Max of Range: 125.000 Degrees F
Min of Range: 40.000 Degrees F
Normal Max of Range: 110.000 Degrees F
Normal Min of Range: 90.000 Degrees F
Thresholds::
Low Critical Threshold: 40.000 Degrees F
Low Major Threshold: 50.000 Degrees F
Low Minor Threshold: 60.000 Degrees F
Up Critical Threshold: 125.000 Degrees F
Up Major Threshold: 120.000 Degrees F
Up Minor Threshold: 110.000 Degrees F
Pos Threshold Hysteresis: 2.000 Degrees F
Neg Threshold Hysteresis: 2.000 Degrees F
RDR[131074]: Sensor[ 2] HS DASD temperature sensor 2 = 35.000
Degrees F
Current Sensor State = UPPER_MINOR
Ranges::
Nominal of Range: 100.000 Degrees F
Max of Range: 125.000 Degrees F
Min of Range: 40.000 Degrees F
Normal Max of Range: 110.000 Degrees F
Normal Min of Range: 90.000 Degrees F
ThresholdsGet ret=INVALID_CMD
RDR[ 65537]: CTRL_RDR Digital Control
RDR[ 65538]: CTRL_RDR Discrete Control
RDR[ 65539]: CTRL_RDR Analog Control
RDR[ 65540]: CTRL_RDR Stream Control
RDR[ 65541]: CTRL_RDR Text Control
RDR[ 65542]: CTRL_RDR Oem Control
RDR[327681]: ANNUNCIATOR_RDR Annunciator 2
RDR[262144]: WATCHDOG_RDR Watchdog 2
RDR[196609]: INVENTORY_RDR Simulator HS DASD Inv 1
I did below changes in client/hpievent.c
198,199c198,201
< rdr.RdrType = SAHPI_NO_RECORD;
< rptentry.ResourceId = 0;
---
> rdr.RdrType = SAHPI_SENSOR_RDR;
> rdr.RecordId = 131073;
> rptentry.ResourceId = 4;
> rptentry.EntryId = 4;
As well changed simulation.data diff is given below:
1181c1181
< value.SensorFloat64=35.000000
---
> value.SensorFloat64=125.000000
Since temperature 125.000000 is in critical threshold of RDR[131073] this
should have generated an event. Please let me know what change I am missing as
I am not getting any event when I run the client.
Regards,
Preeti
-----Original Message-----
From: Preeti Sharma
Sent: Thursday, February 10, 2011 4:55 PM
To: [email protected]
Subject: What changes are required in simulation.data file to see an event?
Hi,
I do not have HPI Chassis yet and want to see an event when I run client
(client/hpievent). For this, do I need a change /etc/openhpi/simulation.data
(sample file provided with openHpi). If any of you already working with real
chassis, could you please provide me a simulation.data file which has an event
entry.
Or if I am wrong above what is the way to see an event when we run
client/hpievent.
Regards,
Preeti
------------------------------------------------------------------------------
The ultimate all-in-one performance toolkit: Intel(R) Parallel Studio XE:
Pinpoint memory and threading errors before they happen.
Find and fix more than 250 security defects in the development cycle.
Locate bottlenecks in serial and parallel code that limit performance.
http://p.sf.net/sfu/intel-dev2devfeb
_______________________________________________
Openhpi-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/openhpi-devel