There are three shelf manager entities in the chassis. Two correspond to the
physical shelf managers. They are:
{ADVANCEDTCA_CHASSIS,1}{SHELF_MANAGER,0}{SHMC,0}
{ADVANCEDTCA_CHASSIS,1}{SHELF_MANAGER,0}{SHMC,1}
There is also a virtual shelf manager that owns the chassis-wide resources. The
virtual shelf manager is actually an application running on the active shelf
manager.
On my system this is the virtual shelf manager:
{ADVANCEDTCA_CHASSIS,1}{OEM_SYSINT_SPECIFIC,1}{SHELF_MANAGER,1}
I can see where this might be a little confusing.
This is what my chassis looks like.
(000):Virtual Shelf Manager:{S|RDR|CNT|RES}
(008):ShMM-500:{S|RDR|INV|RST|FRU|CNT|HS|RES|DIMI|FUMI}
(009):ShMM-500:{S|RDR|INV|RST|FRU|CNT|HS|RES|DIMI|FUMI}
(016):Shelf Resource:{S|RDR|INV|AN|CNT|WDT|RES}
The sensor #133 that reported your event is a chassis-wide System Event sensor
on resource 16.
(133): SENSOR_RDR ID=131205, Ctrl=1, EvtCtrl=RM, Tag=SYSTEM EVENT
Resource Id: 16, Sensor Num: 133, Tag: SYSTEM EVENT
(016):Shelf Resource:{S|RDR|INV|AN|CNT|WDT|RES}
From: Shivegowda, Naveen (NSN - IN/Bangalore) [mailto:[email protected]]
Sent: Friday, May 10, 2013 10:07 AM
To: [email protected]
Subject: Re: [Openhpi-devel] Reg. hpievents -t BLOCK output
Hi Michael,
How to identify virtual and actual shelf manager from the below statement?
>From Resource: {SYSTEM_CHASSIS,1}{SHELF_MANAGER,0}{SHELF_MANAGER,1}
Does virtual shelfmanager corresponds to standby shelfmanager?
Regards
Naveen S
From: ext Thompson, Michael [mailto:[email protected]]
Sent: Friday, May 10, 2013 6:54 PM
To:
[email protected]<mailto:[email protected]>
Subject: Re: [Openhpi-devel] Reg. hpievents -t BLOCK output
Naveen,
I believe that the virtual shelf manager sends events from the HPI System Event
sensor #133 when something in the system configuration has changed.
You can login to the shelf manager and execute the command "clia sensor 20 133
-v" to see the details on the sensor.
You can also execute the shelf manager command "clia sel -v" and look at the
corresponding time stamps to see the what happened near that event.
From: Shivegowda, Naveen (NSN - IN/Bangalore) [mailto:[email protected]]
Sent: Friday, May 10, 2013 8:40 AM
To:
[email protected]<mailto:[email protected]>
Subject: [Openhpi-devel] Reg. hpievents -t BLOCK output
Hi,
When I am doing some tests on my shelf, I am getting few events as shown below:
EntryId: 231
Timestamp: 2013-05-10 14:30:35
Event Type: SENSOR
From Resource: {SYSTEM_CHASSIS,1}{SHELF_MANAGER,0}{SHELF_MANAGER,1}
Event Resource ID: 45
Event Timestamp: 2013-05-10 14:30:35
Event Severity: INFORMATIONAL
Event Sensor Num: 133 (85 hex)
Event Sensor Type: OEM_SENSOR
Event Sensor Category: STATE
Event Sensor Assertion: TRUE
Event Sensor State: STATE_ASSERTED
Optional Data: OEM
OEM: 7e
I am not getting how to understand the above event from resource
perspective(marked with yellow) as it shows 2 shelf manager's.
Regards
Naveen S
------------------------------------------------------------------------------
Learn Graph Databases - Download FREE O'Reilly Book
"Graph Databases" is the definitive new guide to graph databases and
their applications. This 200-page book is written by three acclaimed
leaders in the field. The early access version is available now.
Download your free book today! http://p.sf.net/sfu/neotech_d2d_may
_______________________________________________
Openhpi-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/openhpi-devel