Hi Naveen, IPMI Direct read FRU Info only once, when discovers the FRU. AFAIK there is no good mechanism in IPMI/ATCA to indicate FRU Info change.
On Thu, 20 Feb 2014 08:24:04 +0400, Shivegowda, Naveen (NSN - IN/Bangalore) <[email protected]> wrote: > Hi, > > I use hpiinv to get the hardware inventory information of Atca Shelf. > Recently there was an faulty Fantray(3rd one) which was replaced and Fru > information was updated in the ShelfManager after which hpiinv output > was not displaying any information related to 3rd fantray. > > Once I restarted the Openhpid, hpiinv was able to display the > information for all Fan-tray's. > > Is it required to restart openhpid everytime a FRU(with fru information > updation in ShelfManager) is replaced with new one? > > Regards > Naveen S ------------------------------------------------------------------------------ Managing the Performance of Cloud-Based Applications Take advantage of what the Cloud has to offer - Avoid Common Pitfalls. Read the Whitepaper. http://pubads.g.doubleclick.net/gampad/clk?id=121054471&iu=/4140/ostg.clktrk _______________________________________________ Openhpi-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/openhpi-devel