On Thu, 2005-03-17 at 00:10, Troy Benjegerdes wrote: > But, does this mean > the port is up, or only that the physical link is active?
The port is up. The port state needs to get to active (which is port is up) which won't happen unless port physical state gets to link up. -- Hal > [EMAIL PROTECTED]:/afs/scl/project/infiniband/openib/roland-uverbs/src/bin$ > ./ibstat > CA 'mthca0' > CA type: MT23108 > Number of ports: 2 > Firmware version: 2.0.0 > Hardware version: a1 > Node GUID: 0x0002c90108cd8ba0 > System image GUID: 0x0002c90108cd8ba3 > Port 1: > State: Active > Physical state: LinkUp > Rate: 10 > Base lid: 1 > LMC: 0 > SM lid: 1 > Capability mask: 0x00100a6a > Port GUID: 0x0002c90108cd8ba1 _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general
