On Wed, 2005-06-22 at 19:02 -0700, Roland Dreier wrote: > Josh> I'm trying to figure out how to do an RDMA write with > Josh> immediate data. I've got a regular RDMA write working and > Josh> tried changing wr.opcode from IBV_WR_RDMA_WRITE to > Josh> IBV_WR_RDMA_WRITE_WITH_IMM and stuffing a value in > Josh> wr.imm_data to no avail. The send fails. > > This should work, and in fact I tested it a while ago, although it may > have broken in the meantime. > > When you say that your send fails, what do you mean? Does > ibv_post_send() return immediately with an error? Or do you get a > completion for your send request with a failed status? If so, what is > the status?
I get a completion with failed status 13. Also, it prints out some junk just before the failed completion: [ 0] 007f0406 [ 4] 00cf36ed [ 8] 001da414 [ c] 00003800 [10] 16870000 [14] 00000000 [18] 00000108 [1c] ff100000 Again, this works just fine with IBV_WR_RDMA_WRITE. I'm using 2.6.11.11 with SVN rev 2606. I'll update stuff and try again. -JE > Or does the send just never complete and/or never show up > on the remote system? > > - R. > > _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general