Michael> why dont you decide what size you want and use that? I think we have a bug -- when we calculate the max_inline_data size, we don't take into account the fact that an RDMA write WQE will have a remote address segment.
I'm not sure what the best solution is here. We can report max_inline_data as 16 bytes smaller to handle the RDMA case -- but this means someone doing sends only could actually post more inline data. Or we could split the cap field into max_inline_send_data and max_inline_rdma_write_data and report the two values separately. But that may be too complicated to be worth it. - R. _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general