On Thu, 2005-09-01 at 17:19, Hal Rosenstock wrote: > I've got the merged 1.8.0 OpenSM up and running. I have a number of > questions (which I'll send separately) but the one main problem I have > now is the following: > > I have a 4x HCA port (1x/4x LinkWidthEnable and Supported) connected via > a 1x analyzer connected to a switch (so is 1x LinkWidthActive). > OpenSM does not seem to want to bring this port up. It tries once and > gives up until the physical link is cycled (cable pull and reinsertion). > It does work running over a 4x link with 4x neighbor ports. > > I see the following: > SM side HCA side > Set PortInfo (NoStateChange) -> > <- GetResp PortInfo (Init) > Set PortInfo (Armed) -> > <- GetResp PortInfo (Armed) > Set PortInfo (Active) -> > <- GetResp PortInfo (Init) > > I didn't track the settings on the switch side neighbor port but assume > they mirror this. OpenSM just seems to never try to bring this port > active again without some external stimulus. That's the secondary issue.
Aside from the issue above, I did some Solaris 10 testing today and there appears to be some regression which I need to investigate further. Based on these, I am currently ambivalent about putting the 1.8.0 changes back as yet (even though I was hoping I could go ahead tomorrow AM). Does anybody else have an opinion on this ? -- Hal _______________________________________________ openib-general mailing list openib-general@openib.org http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general