On Wed, 2005-09-07 at 13:00, Eitan Zahavi wrote: > > Also, I see the following messages although these should not be the case: > > Sep 06 15:41:48 725691 [B76A4C40] -> __match_notice_to_inf_rec: ERR 0207: > > Cannot find destination port with LID:0x0007 > This means that the LID of the port registered as the source for this inform > info is not recognized as a valid LID. > > ... > > Sep 06 15:41:48 726186 [B76A4C40] -> __match_notice_to_inf_rec: ERR 0207: > > Cannot find source port with GUID:0x0008f10403960559 > The meaning of this is that the incoming trap source is not a recognized > (included in the SM database) guid
Both this LID and GUID were discovered so I don't understand how this is the case. I can send the log separately if interested (it is over >1M gzipped). -- Hal _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general