On Fri, 2005-09-23 at 13:50, Viswanath Krishnamurthy wrote: > - After 7-8 iterations, I ran into a weird problem, where opensm was > showing the HCA as UNKNOWN. The port > never came up to ACTIVE state. The unplugged and replugged into > different slots, the port remained in INIT > state.
Mellanox : SW : 12 : INI : : : 2048 : 1x : 2.5 : 0002c9010d26e780 : UNKNOWN OpenSM thinks that either there is no physical port on the other end of the link or it is not "valid" (GUID non 0). Obviously it is there as the port state is INIT so the physical link came up which requires the remote end to be there. One other note is that it appears to have come up as 1x. Is that what should happen ? -- Hal _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general