You should not get more then one SA header. I assumed you are doing GetTable of PortInfoRecord. If this is correct you should only get one SA header in the resulting RMPP (reassembled MAD).
EZ Eitan Zahavi Design Technology Director Mellanox Technologies LTD Tel:+972-4-9097208 Fax:+972-4-9593245 P.O. Box 586 Yokneam 20692 ISRAEL > -----Original Message----- > From: Roland Dreier [mailto:[EMAIL PROTECTED] > Sent: Tuesday, November 15, 2005 5:31 PM > To: Hal Rosenstock > Cc: Eitan Zahavi; Roland Dreier; [email protected] > Subject: Re: [openib-general] SRP device management client (and a few > opensmglitches) > > Hal> Are those the only component fields which were zeroed out ? > > No, for example the capability mask is all 0 as well. > > It seems to be something a little bit more complicated. In my test > fabric, which has a single 24-port switch with hosts connected to > both port 1 and port 2 (of the switch), I see no extra entries for my > port 1 query. For my port 2 query, I get exactly 24 entries with a > base_lid of zero and a local port number of 2. The PortNum in the SA > header goes from 1 through 24. > > - R. _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general