Quoting r. Lakshmanan, Madhu <[EMAIL PROTECTED]>:
> Subject: RE: [openib-general] [PATCH] IB/SRP: Enable multichannel
> 
> Quoting r.  Vu Pham [EMAIL PROTECTED]:
> > Subject: Re: [PATCH] IB/SRP: Enable multichannel
> > What is the advantage to have multiple connections/qps on the same
> >physical port to the same target? The disavantages are wasting
> >resources, instability, no fail-over on physical port error...
> 
> The advantage is if the target in question is an IOC that connects to a
> FC SAN for example. In this case, the host is physically connected to
> the same IOC, but can maintain independent logical connections to
> specific storage devices on the SAN that are "behind" the IOC.

We could just let the user specify the Id Ext when adding the device.
How does this sound?

-- 
MST

_______________________________________________
openib-general mailing list
[email protected]
http://openib.org/mailman/listinfo/openib-general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general

Reply via email to