On Mon, Oct 3, 2011 at 19:16, Jason Matthews <ja...@broken.net> wrote: > I wrote a script, it is very rough and would require some tuning for your > config, but it might solve your problem if your hardware is compatible. > > Compatible means, LSI controller and disk shelf that is SES2 compliant, > supports page code 0xa, additional element status and sets the element > index present bit. If your gear does that, then I have a script that could > help you. > > If you meet these restrictions, I will publish it some where along with the > sas2ircu binary that I lifted from SMC. > > j.
I have also managed to write a script to control the fault and identification lights on the JBOD using SES2 and informations from this post: http://www.spinics.net/lists/linux-scsi/msg50273.html The hardware I am using is a LSI 9201-16e controller, connected through a LSI SAS6160 switch to a LSI DE1600 JBOD array, so they should be compatible. I am very interested in how you are doing things in your script, so please put it up somewhere. -- Venlig hilsen / Kind regards Jeppe Toustrup (aka. Tenzer) _______________________________________________ OpenIndiana-discuss mailing list OpenIndiana-discuss@openindiana.org http://openindiana.org/mailman/listinfo/openindiana-discuss