Hi Guys,

I'm writing application which uses OpenIPMI v2.0.22 library SEL mechanism 
similar to eventd.c sample application. I register threshold and discrete event 
handlers for available sensors for domain called mydomain2. When I generate 
event using ipmitool I'm receive event successfully but it comes twice and all 
the data is the same (duplicated). After investigation it looks like event is 
invoked from different MCs. I'm seeing that OpenIPMI lib handler 
(handle_sel_data()) is called for MC names "mydomain2(0.20)" and 
"mydomain2(6.20)". In my event handler I'm calling ipmi_sensor_get_mc() and 
ipmi_mc_get_name() to understand which MC the sensor belongs to and it returns 
"mydomain2(0.20)". Also I added event handler for SMI interface and when the 
event arrives there are no doubled events observed.

Does anybody has seen this issue? Is this behavior expected? What is the reason 
I'm receiving events twice?

Regards,
Roman.
--------------------------------------------------------------