--On Thursday, February 05, 2009 6:26 AM +0100 Emmanuel Dreyfus
<[email protected]> wrote:
Pierangelo Masarati <[email protected]> wrote:
According to the above logs, the consumer fails within an internal
modify. It could be of help to see a little bit more about that modify.
Would it be possible to increase the log level? Adding at least
"sync" could at least tell what was being replicated when the failure
occurred.
Is the problem reproducible? Does it take a lot to reproduce?
It seems to have vanished right now. I hope it will not come again, but
if it does, I will increase log level se see what is going on. What
level to you want?
As he said, at least add "sync".
--Quanah
--
Quanah Gibson-Mount
Principal Software Engineer
Zimbra, Inc
--------------------
Zimbra :: the leader in open source messaging and collaboration