Thanks for your help Mauricio,
If a replica is too far out of sync (or completely empty), conventional 
syncrepl is used to bring it up to date and replication then switches back to 
the delta-syncrepl mode.
When i modify a hug group with memberof overlay activated, the syncrepl is used 
instead of delta-syncrepl
I don't want that the provider replace the entire entry in the replica, but 
update only the modified attributs, is there a configuration to avoid this kind 
of behavior ?

Thanks

----- Mail original -----
De: "Mauricio Tavares" <[email protected]>
À: [email protected]
Envoyé: Mardi 28 Février 2012 20:42:40
Objet: Re: Delta-syncrepl issue

On Tue, Feb 28, 2012 at 1:24 PM, Quanah Gibson-Mount <[email protected]> wrote:
> --On Tuesday, February 28, 2012 3:54 PM +0100 Abderamane Hamani
> <[email protected]> wrote:
>
>> Good morning,
>> Is it possible to use always delta-syncrepl even the replica consumer is
>> too far from the provider ?? Many thanks in advance
>
>
> Your question doesn't make sense as worded.  Delta-syncrepl is not limited
> by physical distance.
>
> --Quanah
>
     Also, depending on the traffic and connection speed between both
machines, you might experience some slowdown, but it will just catch
up eventually. Unless you keep changing your ldap database all the
time. ;)

> --
>
> Quanah Gibson-Mount
> Sr. Member of Technical Staff
> Zimbra, Inc
> A Division of VMware, Inc.
> --------------------
> Zimbra ::  the leader in open source messaging and collaboration
>