Hi

> Phil Pishioneri <p...@psu.edu> hat am 29.07.2025 14:37 CEST geschrieben:
> 
> > 
> > Hi!
> > 
> >  
> > 
> > I had a similar situation with delta-syncrepl, and I’d wish there were a 
> > tool like “touch” to force sending out the current object to the other 
> > servers. This problem is specific to delta-syncrepl, I guess (as the other 
> > methods will most likely “pull” any missing objects)
> > 
> 
> To force an object to sync I used to modify or temporarily add an attribute 
> not relevant to the object. Typically, in my case, I added "description", let 
> the object sync, then deleted that attribute.
> 
Thanks for the hint. I did try that also with a description attribute. However 
on the "broken" provider server the object still was just a glue object and did 
not get synced despite the new attribute.
I will try Howards suggestion with the manageDSAit control.
 
Best regards,
Cyril

Reply via email to