Hi,

Spencer Oliver wrote:
> On 18 January 2012 14:20, Jonathan Dumaresq <[email protected]>
> wrote: 
>>>> 
>>>> How Do I clear the Readout option with OpenOCD ?
>>>> 
>>> 
>>> use the unlock cmd
>>> 
>> Mmm... This command send the 0x5AA5 to the RDP. On the stm32f0x it's
>> 0xAA55. I try to change that, but that don't work ethier. When I
>> look the USB traffic with the ST-LINK utility, They always use the
>> flash helper 
>> software in ram to modify the RDP bytes. I wonder If we can change
>> the 
>> RDP from the debugger when the Readout protection is enabled ?
>> 
> 
> It also seems that the M0 parts have an added protection level - Level
> 2 that completely disables all debug.
Yes, 

>From whata I see most of the time is level 1. When I got Level 1 I could not
remove it with openOCD. Even with the ST_LINK utility, I have hardtime to
get it removed. The only way that I have found is to use the program funtion
(flash program) and the utility tell me that the Level 1 is there and it
will remove temporary.

I continue digging with all theses...

Jonathan
> 
> Cheers
> Spen



------------------------------------------------------------------------------
Keep Your Developer Skills Current with LearnDevNow!