> > Afraid not, however the stlink should be using the cortex-m3
> > SYSRESETREQ, on the stm32 should behave like a srst reset (from the
> > software point of view).
> >
> 
> Just looked into this and it seems that they are not using the
> SYSRESETREQ - ST fail.
> 

It looks that I solved the problem with
mww 0xE000EDF0 0xa05f0000
at the end of openocd script. Now I don't need to replug the USB cable after 
openocd sctipt ends.

Maybe you could update openocd scripts for STLink V2 ?

Vaclav

------------------------------------------------------------------------------