> > Afraid not, however the stlink should be using the cortex-m3 > > SYSRESETREQ, on the stm32 should behave like a srst reset (from the > > software point of view). > > > > Just looked into this and it seems that they are not using the > SYSRESETREQ - ST fail. >
It looks that I solved the problem with mww 0xE000EDF0 0xa05f0000 at the end of openocd script. Now I don't need to replug the USB cable after openocd sctipt ends. Maybe you could update openocd scripts for STLink V2 ? Vaclav ------------------------------------------------------------------------------ Better than sec? Nothing is better than sec when it comes to monitoring Big Data applications. Try Boundary one-second resolution app monitoring today. Free. http://p.sf.net/sfu/Boundary-dev2dev _______________________________________________ OpenOCD-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/openocd-devel