Ack,
Mathi.

> -----Original Message-----
> From: Anders Widell [mailto:anders.wid...@ericsson.com]
> Sent: Friday, March 18, 2016 9:44 PM
> To: Mathivanan Naickan Palanivelu
> Cc: opensaf-devel@lists.sourceforge.net
> Subject: [PATCH 1 of 1] plm: Support up to 4095 nodes [#1613]
> 
>  osaf/services/saf/plmsv/plms/plms_mds.c |  6 +-----
>  1 files changed, 1 insertions(+), 5 deletions(-)
> 
> 
> Use the new support function GetSlotSubslotIdFromNodeId() to extract a
> 32-bit integer containing the slot ID and subslot ID from a Node ID.
> 
> diff --git a/osaf/services/saf/plmsv/plms/plms_mds.c
> b/osaf/services/saf/plmsv/plms/plms_mds.c
> --- a/osaf/services/saf/plmsv/plms/plms_mds.c
> +++ b/osaf/services/saf/plmsv/plms/plms_mds.c
> @@ -40,12 +40,8 @@ void plms_mds_unregister();
> **********************************************************
> *******************/
>  SaUint32T plms_get_slot_and_subslot_id_from_node_id(NCS_NODE_ID
> node_id)  {
> -     NCS_PHY_SLOT_ID phy_slot;
> -     NCS_SUB_SLOT_ID sub_slot;
> -     m_NCS_GET_PHYINFO_FROM_NODE_ID(node_id, NULL, &phy_slot,
> &sub_slot);
> -     return ((sub_slot * NCS_SUB_SLOT_MAX) + (phy_slot));
> +     return GetSlotSubslotIdFromNodeId(node_id);
>  }
> -
> 
> 
> 
> /**********************************************************
> ******************\

------------------------------------------------------------------------------