- **Type**: defect --> enhancement


---

** [tickets:#518] saLogStreamSeverityFilter attribute writable for all streams**

**Status:** unassigned
**Milestone:** future
**Created:** Thu Jul 25, 2013 07:17 AM UTC by Sirisha Alla
**Last Updated:** Fri Aug 02, 2013 01:25 PM UTC
**Owner:** Madhurika Koppula

According to the spec section 3.1.4 Log Filtering based on severity values is 
not supported by the alarm and notification streams as all published alarm and 
notifications must be logged .

In that case the saLogStreamSeverityFilter attribute of the alarm and 
notification streams object should always be set to 127 ( 0x7f which means no 
log is filtered , all log records gets logged ) and should not be a writable 
attribute. 


---