2011/7/19 Peter Koch <p...@opensc-project.org>: > Hi Martin! > > 2011/7/18 Martin Paljak <mar...@martinpaljak.net> >> >> > Some reader expect just 4 bytes (CLA INS P1 P2) without Le. Some other >> > readers insist on getting a 0-Le byte. And very few readers handle both >> > cases. >> >> This should be tested and documented if possible. Creating conditional >> reader-specific code is probably inevitable. > > Maybe Ludouvic can add this information to his CCID reader matrix > http://pcsclite.alioth.debian.org/ccid/iManufacturer.html in the > limitation column
Yes, that is a good idea. I would like to have a correct and precise documentation of the problem (and solution if available). Johannes, can you confirm that using 04:00:00:00 - 00:20:00:00 as suggested by Peter solves the problem with the Xiring MyLeo reader and a TCOS card? Bye -- Dr. Ludovic Rousseau _______________________________________________ opensc-devel mailing list opensc-devel@lists.opensc-project.org http://www.opensc-project.org/mailman/listinfo/opensc-devel