Larry Liu wrote:
> Hi Rick,
>
> Thanks for your suggestion. We made the changes accordingly. That 
> said, by default, sd(7D) will do RMW to misaligned I/O with warning 
> message. Custormers can configure the behavior as do RMW without 
> warning message and do not do RMW with error returned. The 
> configuration will be per device based (PSARC 2008/465 
> [s]sd-config-list). We don't have a mechanism to configure the 
> behavior per partition based.
>
> I attached the modified rmw design doc.
>
> Thanks,
> Larry
>
I am happier with the proposed changes. Thank you

-- 
---------------------------------------------------------------------
Rick Matthews                           email: Rick.Matthews at sun.com
Sun Microsystems, Inc.                  phone:+1(651) 554-1518
1270 Eagan Industrial Road              phone(internal): 54418
Suite 160                               fax:  +1(651) 554-1540
Eagan, MN 55121-1231 USA                main: +1(651) 554-1500          
---------------------------------------------------------------------


Reply via email to