If you are using  modern build ( post B83 )    this  should be possible  
just substitute  rtls0 for  nge0   that I use. 


# dladm show-linkprop -p state nge0
LINK         PROPERTY        VALUE          DEFAULT        POSSIBLE
nge0         state           up             up             up,down 
# dladm show-linkprop -p duplex nge0
LINK         PROPERTY        VALUE          DEFAULT        POSSIBLE
nge0         duplex          full           --             half,full 
# dladm show-linkprop -p speed nge0
LINK         PROPERTY        VALUE          DEFAULT        POSSIBLE
nge0         speed           1000           --             -- 
# dladm show-linkprop -p flowctrl nge0
LINK         PROPERTY        VALUE          DEFAULT        POSSIBLE
nge0         flowctrl        no             bi             no,tx,rx,bi 


 Your problem is probably a marginal  Cable. 
 I had a  45 feet  ( 15 meter )  cable  ( cat5 )   that I had to change because 
it did 
not work reliably at 100 Mbit 

 //Lars
 
 
This message posted from opensolaris.org

Reply via email to