On Mon, Jul 13, 2009, Chris Bare wrote:

> I'm trying to log the exact data I am sending to the server by doing this:
> 
>       if (!i2d_CMS_bio_stream (server, cms, mem, flags))
>               // error
>       BIO_reset(mem);
>       if (!i2d_CMS_bio_stream (logfile, cms, mem, flags))
>               // err
> 
> I get no error for the second call to i2d_CMS_bio_stream, but I also get 0
> bytes output to the file. If I comment out the first call, it works fine.
> 
> Is there something else I need to reset, or once it's sent, do I have to start
> all over with a new cms object?
> 

That's not something I planned for during the implementation. If you want to
log the data you're about to send then that's easy enough, just call
BIO_get_mem_data() after the first call.

Steve.
--
Dr Stephen N. Henson. OpenSSL project core developer.
Commercial tech support now available see: http://www.openssl.org
______________________________________________________________________
OpenSSL Project                                 http://www.openssl.org
User Support Mailing List                    [email protected]
Automated List Manager                           [email protected]

Reply via email to