On Thu, Aug 01 2013, Sandy Walsh wrote:

> Hmm, if notifications are turned on, it should fill up. For billing
> purposes we don't want to lose events simply because there is no
> consumer. Operations would alert on it and someone would need to put out
> the fire.

So currently, are we're possibly losing events because we don't use the
standard queue but one defined by Ceilometer upon connection?
We can't consume events from the default notifications queue or we would
break any tool possibly using it. Each tool consuming needs a copy of
them.

Isn't there a way to queue the message in exchanges if there's no queue
at all?

-- 
Julien Danjou