One fairly common failure mode folk run into is registering a node with a nova-bm/ironic environment that is itself part of that environment. E.g. if you deploy ironic-conductor using Ironic (scaling out a cluster say), that conductor can then potentially power itself off if the node that represents itself happens to map to it in the hash ring. It happens manually too when folk just are entering lots of nodes and don't realise one of them is also a deployment server :).
I'm thinking that a good solution will have the following properties: - its possible to manually guard against this - we can easily make the guard work for nova deployed machines And that we don't need to worry about: - arbitrary other machines in the cluster (because thats a heat responsibility, to not request redeploy of too many machines at once). For now, I only want to think about solving this for Ironic :). I think the following design might work: - a config knob in ironic-conductor that specifies its own pm_address - we push that back up as part of the hash ring metadata - in the hash ring don't set a primary or fallback conductor if the node pm address matches the conductor self pm address - in the Nova Ironic driver add instance metadata with the pm address (only) of the node Then we can just glue the instance metadata field to the conductor config key. -Rob -- Robert Collins <[email protected]> Distinguished Technologist HP Converged Cloud _______________________________________________ OpenStack-dev mailing list [email protected] http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev