On 30/07/2015 1:55 PM, Srikanth Vavilapalli wrote:
I was able to resolve this issue by adding the following configuration line (by
default, disable_non_metric_meters is set to True, and most of the Neutron
meters are of type non-metric) in /etc/ceilometer/ceilometer.conf and
restarting all ceilometer services.. Hope this helps others...
[notification]
disable_non_metric_meters = false
to followup, in Ceilometer, we capture data in two different models:
Meters and Events[1]. Meters are designed for numeric, measurement data
such as: cpu time, cpu_util, incoming.bytes, etc... Events are a more
generic model which represent the state of a resource. historically, we
never had Events so we captured non-measurement data (see Neutron
'meters') as Meters. going forward, consumers should enable store_events
(if not already) to capture non-measurement data as Events. Events offer
better granularity and are more query-able.
[1]
http://docs.openstack.org/admin-guide-cloud/content/section_telemetry-events.html
cheers,
--
gord