> From: Eduard Matei [mailto:[email protected]] > Sent: Tuesday, September 15, 2015 4:04 PM > > Hi, > > This all started when we were testing Evacuate with our storage driver. > We thought we found a bug > (https://bugs.launchpad.net/cinder/+bug/1491276) then Scott replied that > we should be running cinder-volume service separate from nova-compute. > For some internal reasons we can't do that - yet, but we have some > questions regarding the behavior of the service: > > - on our original test setup we have 3 nodes (1 controller + compute + cinder, > 2 compute + cinder). > -- when we shutdown the second node and tried to evacuate, the call was > routed to cinder-volume of the halted node instead of going to other nodes > (there were still 2 cinder-volume services up) - WHY?
Cinder assumes that each c-vol can control only volumes which were scheduled onto it. As volume services are differentiated by hostname a known workaround is to set same value for host option in cinder.conf on each of the c-vols. This will make c-vols to listen on the same queue. You may however encounter some race conditions when running such configuration in Active/Active manner. Generally recommended approach is to use Pacemaker and run such c-vols in Active/Passive mode. Also expect that scheduler's decision will be generally ignored - as all the nodes are listening on the same queue. > - on the new planned setup we will have 6 nodes (3 dedicated controller + > cinder-volume, 3 compute) > -- in this case which cinder-volume will manage which volume on which > compute node? Same situation - a volume will be controlled by c-vol which created it. > -- what if: one compute node and one controller go down - will the Evacuate > still work if one of the cinder-volume services is down? How can we tell - for > sure - that this setup will work in case ANY 1 controller and 1 compute nodes > go down? The best idea is I think to use c-vol + Pacemaker in A/P manner. Pacemaker will make sure that on failure a new c-vol is spun up. Where are volumes physically in case of your driver? Is it like LVM driver (volume lies on the node which is running c-vol) or Ceph (Ceph takes care where volume will land physically, c-vol is just a proxy). > > Hypothetical: > - if 3 dedicated controller + cinder-volume nodes work can perform evacuate > when one of them is down (at the same time with one compute), WHY can't > the same 3 nodes perform evacuate when compute services is running on > the same nodes (so 1 cinder is down and 1 compute) I think I've explained that. > - if the answer to above question is "They can't " then what is the purpose of > running 3 cinder-volume services if they can't handle one failure? Running 3 c-vols is beneficial if you have multiple backends or use LVM driver. > - and if the answer to above question is "You only run one cinder-volume" > then how can it handle failure of controller node? I've explained that too. There are efforts in the community to make it possible to run c-vol in A/A, but I don't think there's ETA yet. > > Thanks, > > Eduard __________________________________________________________________________ OpenStack Development Mailing List (not for usage questions) Unsubscribe: [email protected]?subject:unsubscribe http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev