On 13 June 2016 at 22:22, Terry Wilson <[email protected]> wrote: > > So basically, as long as we try to plug ports with different MTUs into > the same bridge, we are utilizing a bug in Open vSwitch, that may break us > any time. > > > > I guess our alternatives are: > > - either redesign bridge setup for openvswitch to e.g. maintain a bridge > per network; > > - or talk to ovs folks on whether they may support that for us. > > > > I understand the former option is too scary. It opens lots of questions, > including upgrade impact since it will obviously introduce a dataplane > downtime. That would be a huge shift in paradigm, probably too huge to > swallow. The latter option may not fly with vswitch folks. Any better ideas? > > I know I've heard from people who'd like to be able to support both > DPDK and non-DPDK workloads on the same node. The current > implementation with a single br-int (and thus datapath) makes that > impossible to pull of with good performance. So there may be other > reasons to consider introducing multiple isolated bridges: MTUs, > datapath_types, etc. >
Incidentally this is something that Nova is already capable of handling (ie. wiring VM's in different bridges) thanks to [1], and with some minor additions as being discussed in the context of [2] vlan-aware-vms, we can open up the possibility to this deployment model in a not so distant future. [1] https://blueprints.launchpad.net/nova/+spec/neutron-ovs-bridge-name [2] http://lists.openstack.org/pipermail/openstack-dev/2016-June/097025.html > Terry > > On Mon, Jun 13, 2016 at 11:49 AM, Ihar Hrachyshka <[email protected]> > wrote: > > Hi all, > > > > in Mitaka, we introduced a bunch of changes to the way we handle MTU in > Neutron/Nova, making sure that the whole instance data path, starting from > instance internal interface, thru hybrid bridge, into the br-int; as well > as router data path (qr) have proper MTU value set on all participating > devices. On hypervisor side, both Nova and Neutron take part in it, setting > it with ip-link tool based on what Neutron plugin calculates for us. So far > so good. > > > > Turns out that for OVS, it does not work as expected in regards to > br-int. There was a bug reported lately: > https://launchpad.net/bugs/1590397 > > > > Briefly, when we try to set MTU on a device that is plugged into a > bridge, and if the bridge already has another port with lower MTU, the > bridge itself inherits MTU from that latter port, and Linux kernel (?) does > not allow to set MTU on the first device at all, making ip link calls > ineffective. > > > > AFAIU this behaviour is consistent with Linux bridging rules: you can’t > have ports of different MTU plugged into the same bridge. > > > > Now, that’s a huge problem for Neutron, because we plug ports that > belong to different networks (and that hence may have different MTUs) into > the same br-int bridge. > > > > So I played with the code locally a bit and spotted that currently, we > set MTU for router ports before we move their devices into router > namespaces. And once the device is in a namespace, ip-link actually works. > So I wrote a fix with a functional test that proves the point: > https://review.openstack.org/#/c/327651/ The fix was validated by the > reporter of the original bug and seems to fix the issue for him. > > > > It’s suspicious that it works from inside a namespace but not when the > device is still in the root namespace. So I reached out to Jiri Benc from > our local Open vSwitch team, and here is a quote: > > > > === > > > > "It's a bug in ovs-vswitchd. It doesn't see the interface that's in > > other netns and thus cannot enforce the correct MTU. > > > > We'll hopefully fix it and disallow incorrect MTU setting even across > > namespaces. However, it requires significant effort and rework of ovs > > name space handling. > > > > You should not depend on the current buggy behavior. Don't set MTU of > > the internal interfaces higher than the rest of the bridge, it's not > > supported. Hacking this around by moving the interface to a netns is > > exploiting of a bug. > > > > We can certainly discuss whether this limitation could be relaxed. > > Honestly, I don't know, it's for a discussion upstream. But as of now, > > it's not supported and you should not do it.” > > > > So basically, as long as we try to plug ports with different MTUs into > the same bridge, we are utilizing a bug in Open vSwitch, that may break us > any time. > > > > I guess our alternatives are: > > - either redesign bridge setup for openvswitch to e.g. maintain a bridge > per network; > > - or talk to ovs folks on whether they may support that for us. > > > > I understand the former option is too scary. It opens lots of questions, > including upgrade impact since it will obviously introduce a dataplane > downtime. That would be a huge shift in paradigm, probably too huge to > swallow. The latter option may not fly with vswitch folks. Any better ideas? > > > > It’s also not clear whether we want to proceed with my immediate fix. > Advices are welcome. > > > > Thanks, > > Ihar > > > __________________________________________________________________________ > > OpenStack Development Mailing List (not for usage questions) > > Unsubscribe: > [email protected]?subject:unsubscribe > > http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev > > __________________________________________________________________________ > OpenStack Development Mailing List (not for usage questions) > Unsubscribe: [email protected]?subject:unsubscribe > http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev >
__________________________________________________________________________ OpenStack Development Mailing List (not for usage questions) Unsubscribe: [email protected]?subject:unsubscribe http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev