> What I'm looking for is the "correct" way to triggers scan on OpenVAS
> without having to wait that 10minute delay each time.

What you're doing is "correct".  You could also use the same OMP connection
multiple times.  That way the Manager would only connect to the Scanner the
first time.  A new connection each time is more resistant to bugs and leaks
in the Manager though.

--
Greenbone Networks GmbH
Neuer Graben 17, 49074 Osnabrueck, Germany | AG Osnabrueck, HR B 202460
Executive Directors: Lukas Grunwald, Dr. Jan-Oliver Wagner
_______________________________________________
Openvas-discuss mailing list
[email protected]
http://lists.wald.intevation.org/cgi-bin/mailman/listinfo/openvas-discuss

Reply via email to