On 01/08/13 13:02, Yousong Zhou wrote:
Hi, this series tries to fix unintended failsafe triggering by initializing
buttons' last_status with its actual value instead of always 0 (released).
Otherwise devices with like TL-WR720N-v3 would always go into failsafe as some 
of
its GPIO buttons are always in pressed state.  It's weird that this issue never
happened before.


Thank you,

the bug has always been there. before procd it seems to have never been triggered/noticed.

        John