On 01/28/2015 11:00 PM, John Crispin wrote: > > > On 28/01/2015 21:31, Matthias Schiffer wrote: >> On 01/28/2015 11:54 AM, John Crispin wrote: [...] >>> this should not break anything with multiple ubus calls. the >>> default behavior also wont change as we set >>> cfg->multicast_querier = true; >>> >>> Please make those changes to the patch and resend it. >> I just re-read the whole function and noticed why I made my change >> like this in the first place: all values in bridge_config are >> always reset to their defaults at the top of >> bridge_apply_settings() anyways, not regarding if the blobmsg >> contains a new value for the options or not. >> > > yep, i will cook up a patch tomorrow ...
Hi, any news on this? > >> Doesn't this mean that all option's values are lost in the case of >> multiple ubus calls anyways? Is this intended for bridge devices, >> or should this be fixed as well? >> > > probably not > >> I hope I don't misunderstand how this is supposed to work, I'm not >> really familar with the way dynamic reconfiguration works in >> netifd... >> > > me neither :) >
signature.asc
Description: OpenPGP digital signature