Thank you for help Gabor.

On 6 June 2013 09:01, Gabor Juhos <[email protected]> wrote:

> Hi Damian,
>
> > I have spot something has changed on my RB750GL syslog after few
> reflashes:
> >
> > was:
> >
> > [    0.000000] MyLoader: sysp=1040433b, boardp=46069909, parts=01009703
> >
> > is:
> >
> > [    0.000000] MyLoader: sysp=00000000, boardp=00000000, parts=00000000
> >
> >
> > Searched here [1] trying to figure out what does this loader parse.
> Seems it's
> > something for Compex boards? As I suppose some parts of flash or
> something has
> > been erased and some info was lost?
> >
> > Do I have to worry about my Mikrotik board now? What does MyLoader do?
> What are
> > those parsed values used for?
>
> You don't have to worry about this. MyLoader is a bootloader used on Compex
> devices and it uses fixed memory locations to pass various data to the
> kernel.
> The prom code checks these memory locations to see that the kernel is
> running on
> a Compex board or not.
>
> -Gabor
>