Hi Lex, While I have no idea what the root of your problem is, it is probably worth to check if it is related to the multi-segment well model: just pass the --use-multisegment-well=false command line parameter to your simulator.
cheers Andreas On Tuesday, 2 July 2019 17:44:11 CEST Lex Rijkels wrote: > Dear OPM community, > Has the SHUT functionality maybe changed in version 2019.04 of Flow? I am > running a simple well test forecast and my well does not react to: > WELOPEN > WELLNAME SHUT / > / > > It simply continues producing. It does stop with STOP (but then I lose the > reported FBHP) or a rate constraint of 0. > Have I missed something in the use of SHUT? > Thanks for your help, > Kind regards, > Lex Rijkels > _______________________________________________ > Opm mailing list > [email protected] > https://opm-project.org/cgi-bin/mailman/listinfo/opm -- The graveyards are full of people the world could not do without. -- Elbert Hubbart
signature.asc
Description: This is a digitally signed message part.
_______________________________________________ Opm mailing list [email protected] https://opm-project.org/cgi-bin/mailman/listinfo/opm