Hi list,
I've upgraded my bridge relay from 0.2.1.26 to 0.2.1.27 yesterday. While rotating logs a HUP gets issued. The log shows: Dec 08 03:10:06.854 [warn] Could not bind to 0.0.0.0:443: Permission denied Dec 08 03:10:06.857 [warn] Failed to parse/validate config: Failed to bind one of the listener ports. Dec 08 03:10:06.857 [err] Reading config failed--see warnings above. For usage, try -h. Dec 08 03:10:06.857 [warn] Restart failed (config error?). Exiting. The config has "User tor", the daemon gets started as root. After dropping priviledges, binding to <1024 might fail. Is the rebinding of the or-port on HUP a new "feature"? Do I have to update the RC script to include any new options to make this work? What else could have caused this, if anything? Sincerely Sebastian *********************************************************************** To unsubscribe, send an e-mail to [email protected] with unsubscribe or-talk in the body. http://archives.seul.org/or/talk/