"Sean Andersen" <[email protected]> wrote on 11/08/2009 22:41:27: > > You should use unique IP addresses or unnumber them to another interface > that is up all the time (e.g. loopback, or Ethernet) and make sure that ospf > is running on the interface (loopback or ethernet) that you are using for > unnumbered (do not unnumber one ptp to another ptp)
Why do I have to? What you describe is common practise but is not the same as one isn't allowed to. Jocke > > Sean > > -----Original Message----- > From: [email protected] [mailto:[email protected]] On Behalf Of > Joakim Tjernlund > Sent: Tuesday, August 11, 2009 12:13 PM > To: [email protected] > Subject: [OSPF] multilple numbered PtoP links with the same local IP address > > > Is there something in the OSPF spec which prevents it from operate > on multiple PtoP interfaces with the same local IP address? > > I have that working, but there are arguments that this is allowed by > OSPF, i.e, ethier use unnumbered links or unique local IP addresses. > > Jocke _______________________________________________ OSPF mailing list [email protected] https://www.ietf.org/mailman/listinfo/ospf