Zakhar Levchenko wrote:
> Hi,
>
> With the attached patch envy24ht devices should not change sample rate 
> directly in 
> envy24ht_set_rate(), but do it in envy24ht_prepare_for_input() or 
> envy24ht_prepare_for_output().
> Thus unnecessary sample rate switches are eliminated. I've also 
> made small changes in envy24ht_open_input() and envy24ht_open_output() where 
> postfix increment expressions are used incorrectly. 
> Changing pending_speed_sel should be permitted for the first opened 
> device, but not for the the second as it was previously.
>
Many thanks Zakhar! The updated version is now in the hg server.

Best regards,

Hannu

_______________________________________________
oss-devel mailing list
oss-devel@mailman.opensound.com
http://mailman.opensound.com/mailman/listinfo/oss-devel