Dear Mickael or to whom it may concern,

I would like to reactivate this topic since the problem still exists. I 
would like to preprocess a SPOT 5 SPOTView Level 3 (Ortho) scene using the 
following command:

otbcli_OpticalCalibration -progress 1 -in ...\IMAGERY.TIF -out 
...\test_toa.tif -level toa

However I receive the following error message:

ossimSpotDimapSupportData::loadXmlFile 
DEBUG:ossimSpotDimapSupportData::loadXmlFile:
Scene source initialization failed.  Returning false
ossimSpotDimapSupportData::loadXmlFile 
DEBUG:ossimSpotDimapSupportData::loadXmlFile:
Scene source initialization failed.  Returning false
2014 Mar 11 14:32:23  :  Application.logger  (FATAL) The following error 
occurred during application execution : 
c:\users\jmalik\dashboard\src\otb\code\io\otbOp
ticalDefaultImageMetadataInterface.h:63:
itk::ERROR: OpticalDefaultImageMetadataInterface(038A4718): GetPhysicalGain 
not implemented in OpticalDefaultImageMetadataInterface, no captor type 
found


The problem seems to be the same as with Wesley. However there is gain and 
bias available in my metadata, so it should work. Is there any solution for 
this?


Thanks,

T


On Thursday, March 14, 2013 11:07:18 AM UTC+1, Mickaël Savinaud wrote:
>
>  HI Wesley,
>
> Another strategy to perform the processing with the physical gain and bias 
> will be to use the bandMath application [1].
> You can find some information about how to make atmospheric correction in 
> the chapter 12.2 of the OTB Software guide [2]. More precisely, you can 
> find the mathematical expression to use with the BandMath.
> Best
> Mickael 
>
> [1] http://orfeo-toolbox.org/CookBook/CookBooksu111.html#x143-8150004.10.1
> [2] 
> http://orfeo-toolbox.org/SoftwareGuide/SoftwareGuidech12.html#x38-20900012.2
>
> Le 14/03/2013 09:57, Mickael Savinaud a écrit :
>  
> Hi Wesley,
>
> Could you send me the dimap file please.
> Best
> Mickaël
>
> Le 14/03/2013 08:33, Jonathan Roberts a écrit :
>  
>  Hi Mickael,
>
>  Many thanks for your reply. I took your advice and ran the 
> otbcli_OpticalCalibration with the level switch set to toa and received the 
> following error, see below. I perhaps should have provided some additional 
> information about the imagery in my original post. The data is formatted in 
> DIMAP format which is the standard SPOT distribution format. The actual 
> imagery is processed to SPOTView ORTHO BASIC with a spatialtion resolution 
> of 2,5m. I am concerned that the metadata for the imagery does not contain 
> the necessary gains and biases required for DN to radiance conversions. I 
> fear that I may have to do the processing by hand using band mathematics 
> and running a standalone version of 6S to undertake the atmospheric 
> correction.
>  
>  Regards,
>  Wesley
>
>
>
>
>
>
>
>
>
> *wes...@ubuntu32:~/work/2006/DATA_N2310.87_E195.73/SPVIEW__2013_0$ 
> <javascript:> otbcli_OpticalCalibration -in IMAGERY.TIF -level toa -out 
> SPOT_Calibrate.tif OpticalCalibration -in IMAGERY.TIF -level toa -out 
> SPOT_Calibrate.tif ossimSpotDimapSupportData::loadXmlFile 
> DEBUG:ossimSpotDimapSupportData::loadXmlFile: Scene source initialization 
> failed.  Returning false ossimSpotDimapSupportData::loadXmlFile 
> DEBUG:ossimSpotDimapSupportData::loadXmlFile: Scene source initialization 
> failed.  Returning false 2013 Mar 14 09:10:52  :  Application.logger  
> (FATAL) The following error occurred during application execution : 
> /build/buildd/otb-3.16.0/Code/IO/otbOpticalDefaultImageMetadataInterface.h:63:
>  
> itk::ERROR: OpticalDefaultImageMetadataInterface(0x9c34238): 
> GetPhysicalGain not implemented in OpticalDefaultImageMetadataInterface, no 
> captor type found*
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>  
>
> On Wed, Mar 13, 2013 at 6:21 PM, Mickael Savinaud 
> <[email protected]<javascript:>
> > wrote:
>
>> Hi Wesley,
>>
>> Could you try with OpticalCalibration -in IMAGERY.TIF -level toa -out 
>> SPOT_Calibrate.tif please ?
>> Best
>> Mickaël
>>
>>
>> Le 13/03/2013 10:08, Jonathan Roberts a écrit :
>>
>>>  Dear Colleagues,
>>>
>>> Our organisation was recently awarded several high resolution SPOT 
>>> images through the Planet Action initiative.
>>>
>>> I would like to use this imagery to update our GIS database as well as 
>>> creating a number of other important layers pertinent to our project 
>>> (Change Detection, Forest Cover Maps, Land Cover Maps).
>>>
>>> I am interested in using OTB to process the imagery and extract the 
>>> relevant information. A first step in the process is the optical 
>>> calibration of the imagery. I have tried to use the 
>>> otbcli_OpticalCalibration application, unfortunately I received the 
>>> following error which I presume is the result of incomplete metadata. 
>>> Please could you advise on the best way to move forward?
>>>
>>> OpticalCalibration -in METADATA.DIM -level toa -out SPOT_Calibrate.tif
>>> 2013 Mar 11 16:24:06  :  Application.logger  (FATAL) The following error 
>>> occurred during application execution : 
>>> /build/buildd/otb-3.16.0/Code/IO/otbOpticalDefaultImageMetadataInterface.h:63:
>>> itk::ERROR: OpticalDefaultImageMetadataInterface(0x8aac6e8): 
>>> GetPhysicalGain not implemented in OpticalDefaultImageMetadataInterface, no 
>>> captor type found
>>>
>>> Many thanks and kind regards,
>>> Wesley
>>>
>>> -- 
>>> "The shin bone is a device for finding furniture in a dark room."
>>> Anon
>>>  -- 
>>> -- 
>>> Check the OTB FAQ at
>>> http://www.orfeo-toolbox.org/FAQ/
>>>
>>> You received this message because you are subscribed to the Google
>>> Groups "otb-users" group.
>>> To post to this group, send email to [email protected]<javascript:>
>>> To unsubscribe from this group, send email to
>>> [email protected] <javascript:>
>>> For more options, visit this group at
>>> http://groups.google.com/group/otb-users?hl=en
>>>
>>> ---
>>> You received this message because you are subscribed to the Google 
>>> Groups "otb-users" group.
>>> To unsubscribe from this group and stop receiving emails from it, send 
>>> an email to [email protected] <javascript:>.
>>> For more options, visit https://groups.google.com/groups/opt_out.
>>>
>>>
>>>  
>> -- 
>> -- 
>> Check the OTB FAQ at
>> http://www.orfeo-toolbox.org/FAQ/
>>
>> You received this message because you are subscribed to the Google
>> Groups "otb-users" group.
>> To post to this group, send email to [email protected]<javascript:>
>> To unsubscribe from this group, send email to
>> [email protected] <javascript:>
>> For more options, visit this group at
>> http://groups.google.com/group/otb-users?hl=en
>>
>> --- You received this message because you are subscribed to the Google 
>> Groups "otb-users" group.
>> To unsubscribe from this group and stop receiving emails from it, send an 
>> email to [email protected] <javascript:>.
>> For more options, visit https://groups.google.com/groups/opt_out.
>>
>>
>>  
>
>
> -- 
> "The shin bone is a device for finding furniture in a dark room."
> Anon 
>
>
> -- 
>   <http://www.c-s.fr>  *Mickaël SAVINAUD*, *PhD*
> Ingénieur d'études et développement
> Responsable projet OrfeoToolBox
>  *Division ESPACE & 
> Renseignement*<https://thor.si.c-s.fr/blogs/cs-blogs-business/>* 
> - Département APPLICATIONS*
>
> *CS Systèmes d'Information*
> Parc de la Grande Plaine - 5, Rue Brindejonc des Moulinais - BP 15872
> 31506 Toulouse Cedex 05 - FRANCE
> +33 561 17 63 13 / +33 671 57 84 15 - [email protected] <javascript:>   
> -- 
> -- 
> Check the OTB FAQ at
> http://www.orfeo-toolbox.org/FAQ/
>  
> You received this message because you are subscribed to the Google
> Groups "otb-users" group.
> To post to this group, send email to [email protected]<javascript:>
> To unsubscribe from this group, send email to
> [email protected] <javascript:>
> For more options, visit this group at
> http://groups.google.com/group/otb-users?hl=en
>  
> --- 
> You received this message because you are subscribed to the Google Groups 
> "otb-users" group.
> To unsubscribe from this group and stop receiving emails from it, send an 
> email to [email protected] <javascript:>.
> For more options, visit https://groups.google.com/groups/opt_out.
>  
>  
>
>
> -- 
>   <http://www.c-s.fr>  *Mickaël SAVINAUD*, *PhD*
> Ingénieur d'études et développement
> Responsable projet OrfeoToolBox
>  *Division ESPACE & 
> Renseignement*<https://thor.si.c-s.fr/blogs/cs-blogs-business/>* 
> - Département APPLICATIONS*
>
> *CS Systèmes d'Information*
> Parc de la Grande Plaine - 5, Rue Brindejonc des Moulinais - BP 15872
> 31506 Toulouse Cedex 05 - FRANCE
> +33 561 17 63 13 / +33 671 57 84 15 - [email protected] <javascript:>   
>  

-- 
-- 
Check the OTB FAQ at
http://www.orfeo-toolbox.org/FAQ.html

You received this message because you are subscribed to the Google
Groups "otb-users" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to
[email protected]
For more options, visit this group at
http://groups.google.com/group/otb-users?hl=en
--- 
You received this message because you are subscribed to the Google Groups 
"otb-users" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Attachment: METADATA.DIM
Description: Binary data

Reply via email to