On Tue, 2017-03-07 at 17:31 +0300, Ilya Maximets wrote: > Sphynx 1.1.3 on RHEL7 is able to properly build the documentation. > One last thing is that 'ps1con' and 'doscon' lexers are not > supported by available python-pygments-2.0.2. Changing them > to 'ps1' and 'console' accordingly doesn't make many differencies. > > Sphinx discovering fixed because 'sphinx-build v1.1.3' doesn't > support '--version' option. > > Signed-off-by: Ilya Maximets <[email protected]>
I'm generally fine with this, but Darren Ball beat you to the punch [1] and caught one that you seem to have missed (documentation-style.rst)? As such, we only need the modifications to 'conf.py', 'openvswitch.m4' and 'requirements.txt'. Assuming we keep just those changes: Acked-by: Stephen Finucane <[email protected]> Stephen [1] https://patchwork.ozlabs.org/patch/734930/ > --- > > Note: > Marked as RFC because I don't know sphinx well. > > Documentation/conf.py | 2 +- > Documentation/intro/install/windows.rst | 70 ++++++++++++++++------- > ---------- > Documentation/requirements.txt | 2 +- > m4/openvswitch.m4 | 2 +- > 4 files changed, 38 insertions(+), 38 deletions(-) > > diff --git a/Documentation/conf.py b/Documentation/conf.py > index 389ef70..5909669 100644 > --- a/Documentation/conf.py > +++ b/Documentation/conf.py > @@ -30,7 +30,7 @@ except ImportError: > > # If your documentation needs a minimal Sphinx version, state it > here. > # > -needs_sphinx = '1.2' > +needs_sphinx = '1.1' > > # Add any Sphinx extension module names here, as strings. They can > be > # extensions coming with Sphinx (named 'sphinx.ext.*') or your > custom > diff --git a/Documentation/intro/install/windows.rst > b/Documentation/intro/install/windows.rst > index caa9f40..d78a442 100644 > --- a/Documentation/intro/install/windows.rst > +++ b/Documentation/intro/install/windows.rst > @@ -225,7 +225,7 @@ building on Linux, FreeBSD, or NetBSD. > all MinGW sessions and then run the below command from MSVC > developers > command prompt.: > > - .. code-block:: doscon > + .. code-block:: console > > > mingw-get upgrade msys-core-bin=1.0.17-1 > > @@ -276,7 +276,7 @@ Now run ``./uninstall.cmd`` to remove the old > extension. Once complete, run > turn on ``TESTSIGNING`` boot option or 'Disable Driver Signature > Enforcement' during boot. The following commands can be used: > > -.. code-block:: doscon > +.. code-block:: console > > > bcdedit /set LOADOPTIONS DISABLE_INTEGRITY_CHECKS > > bcdedit /set TESTSIGNING ON > @@ -294,7 +294,7 @@ to work (covered later). > The command to create a new switch named 'OVS-Extended-Switch' using > a physical > NIC named 'Ethernet 1' is: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > New-VMSwitch "OVS-Extended-Switch" -NetAdapterName "Ethernet > 1" > > @@ -307,7 +307,7 @@ In the properties of any switch, you should > should now see "Open vSwitch > Extension" under 'Extensions'. Click the check box to enable the > extension. > An alternative way to do the same is to run the following command: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > Enable-VMSwitchExtension "Open vSwitch Extension" OVS- > Extended-Switch > > @@ -330,7 +330,7 @@ database, ovsdb-server. Each machine on which > Open vSwitch is installed should > run its own copy of ovsdb-server. Before ovsdb-server itself can be > started, > configure a database that it can use: > > -.. code-block:: doscon > +.. code-block:: console > > > ovsdb-tool create C:\openvswitch\etc\openvswitch\conf.db \ > C:\openvswitch\usr\share\openvswitch\vswitch.ovsschema > @@ -338,7 +338,7 @@ configure a database that it can use: > Configure ovsdb-server to use database created above and to listen > on a Unix > domain socket: > > -.. code-block:: doscon > +.. code-block:: console > > > ovsdb-server -vfile:info --remote=punix:db.sock --log-file \ > --pidfile --detach > @@ -351,7 +351,7 @@ Initialize the database using ovs-vsctl. This is > only necessary the first time > after you create the database with ovsdb-tool, though running it at > any time is > harmless: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl --no-wait init > > @@ -359,14 +359,14 @@ harmless: > > If you would later like to terminate the started ovsdb-server, > run: > > - .. code-block:: doscon > + .. code-block:: console > > > ovs-appctl -t ovsdb-server exit > > Start the main Open vSwitch daemon, telling it to connect to the > same Unix > domain socket: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vswitchd -vfile:info --log-file --pidfile --detach > > @@ -374,7 +374,7 @@ domain socket: > > If you would like to terminate the started ovs-vswitchd, run: > > - .. code-block:: doscon > + .. code-block:: console > > > ovs-appctl exit > > @@ -394,7 +394,7 @@ Add bridges > Let's start by creating an integration bridge, ``br-int`` and a PIF > bridge, > ``br-pif``: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-br br-int > > ovs-vsctl add-br br-pif > @@ -408,7 +408,7 @@ Let's start by creating an integration bridge, > ``br-int`` and a PIF bridge, > > Validate that ports are added by dumping from both ovs-dpctl and > ovs-vsctl: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-dpctl show > system@ovs-system: > @@ -457,7 +457,7 @@ enable them and set the corresponding values to > it to make them IP-able. > > As a whole example, if we issue the following in a powershell > console: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > Get-NetAdapter | select Name,InterfaceDescription > Name InterfaceDescription > @@ -476,13 +476,13 @@ We can see that we have a switch(external) > created upon adapter name > 'Ethernet0' with the internal ports under name 'br-pif' and 'br- > int'. Thus > resulting into the following ovs-vsctl commands: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-pif Ethernet0 > > Dumping the ports should show the additional ports that were just > added: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-dpctl show > system@ovs-system: > @@ -525,7 +525,7 @@ is being addressed. After assigning the name > ``ovs-port-a``, the VIF is > connected back to the Hyper-V switch with name ``OVS-HV-Switch``, > which is > assumed to be the Hyper-V switch with OVS extension enabled.: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > import-module .\datapath-windows\misc\OVS.psm1 > PS > $vnic = Get-VMNetworkAdapter <Name of the VM> > @@ -536,13 +536,13 @@ assumed to be the Hyper-V switch with OVS > extension enabled.: > > Next, add the VIFs to ``br-int``: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-int ovs-port-a > > Dumping the ports should show the additional ports that were just > added: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-dpctl show > system@ovs-system: > @@ -582,7 +582,7 @@ found at technet_. > For example, to set up a switch team combined from ``Ethernet0 2`` > and > ``Ethernet1 2`` named ``external``: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > Get-NetAdapter > Name InterfaceDescription > @@ -602,7 +602,7 @@ For example, to set up a switch team combined > from ``Ethernet0 2`` and > > This will result in a new adapter bound to the host called > ``external``: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > Get-NetAdapter > Name InterfaceDescription > @@ -617,7 +617,7 @@ This will result in a new adapter bound to the > host called ``external``: > > Next we will set up the Hyper-V VMSwitch on the new adapter > ``external``: > > -.. code-block:: ps1con > +.. code-block:: ps1 > > PS > New-VMSwitch -Name external -NetAdapterName external \ > -AllowManagementOS $false > @@ -628,7 +628,7 @@ Under OVS the adapters under the team > ``external``, ``Ethernet0 2`` and > The following example shows how the bridges look with the NICs being > separated: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl show > 6cd9481b-c249-4ee3-8692-97b399dd29d8 > @@ -653,7 +653,7 @@ Switch VLAN tagging along with patch ports > between ``br-int`` and ``br-pif`` is > used to configure VLAN tagging functionality between two VMs on > different > Hyper-Vs. To start, add a patch port from ``br-int`` to ``br-pif``: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-int patch-to-pif > > ovs-vsctl set interface patch-to-pif type=patch \ > @@ -661,7 +661,7 @@ Hyper-Vs. To start, add a patch port from ``br- > int`` to ``br-pif``: > > Add a patch port from ``br-pif`` to ``br-int``: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-pif patch-to-int > > ovs-vsctl set interface patch-to-int type=patch \ > @@ -669,7 +669,7 @@ Add a patch port from ``br-pif`` to ``br-int``: > > Re-Add the VIF ports with the VLAN tag: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-int ovs-port-a tag=900 > > ovs-vsctl add-port br-int ovs-port-b tag=900 > @@ -681,7 +681,7 @@ The Windows Open vSwitch implementation support > VXLAN and STT tunnels. To add > tunnels. For example, first add the tunnel port between > 172.168.201.101 <-> > 172.168.201.102: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-int tun-1 > > ovs-vsctl set Interface tun-1 type=<port-type> > @@ -692,7 +692,7 @@ tunnels. For example, first add the tunnel port > between 172.168.201.101 <-> > > ...and the tunnel port between 172.168.201.101 <-> 172.168.201.105: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl add-port br-int tun-2 > > ovs-vsctl set Interface tun-2 type=<port-type> > @@ -717,14 +717,14 @@ daemons via ``make install``. > > To start, create the database: > > -.. code-block:: doscon > +.. code-block:: console > > > ovsdb-tool create C:/openvswitch/etc/openvswitch/conf.db \ > "C:/openvswitch/usr/share/openvswitch/vswitch.ovsschema" > > Create the ovsdb-server service and start it: > > -.. code-block:: doscon > +.. code-block:: console > > > sc create ovsdb-server \ > binpath="C:/openvswitch/usr/sbin/ovsdb-server.exe \ > @@ -739,25 +739,25 @@ Create the ovsdb-server service and start it: > paths. You can make sure that the correct path has been > registered with the > Windows services manager by running: > > - .. code-block:: doscon > + .. code-block:: console > > > sc qc ovsdb-server > > Check that the service is healthy by running: > > -.. code-block:: doscon > +.. code-block:: console > > > sc query ovsdb-server > > Initialize the database: > > -.. code-block:: doscon > +.. code-block:: console > > > ovs-vsctl --no-wait init > > Create the ovs-vswitchd service and start it: > > -.. code-block:: doscon > +.. code-block:: console > > > sc create ovs-vswitchd \ > binpath="C:/openvswitch/usr/sbin/ovs-vswitchd.exe \ > @@ -766,13 +766,13 @@ Create the ovs-vswitchd service and start it: > > Check that the service is healthy by running: > > -.. code-block:: doscon > +.. code-block:: console > > > sc query ovs-vswitchd > > To stop and delete the services, run: > > -.. code-block:: doscon > +.. code-block:: console > > > sc stop ovs-vswitchd > > sc stop ovsdb-server > diff --git a/Documentation/requirements.txt > b/Documentation/requirements.txt > index fcc02fd..77130c6 100644 > --- a/Documentation/requirements.txt > +++ b/Documentation/requirements.txt > @@ -1,2 +1,2 @@ > -sphinx>=1.2,<2.0 > +sphinx>=1.1,<2.0 > ovs_sphinx_theme>=1.0,<1.1 > diff --git a/m4/openvswitch.m4 b/m4/openvswitch.m4 > index 07c6191..0b2cc27 100644 > --- a/m4/openvswitch.m4 > +++ b/m4/openvswitch.m4 > @@ -417,7 +417,7 @@ AC_DEFUN([OVS_CHECK_SPHINX], > [AC_CACHE_CHECK( > [for sphinx], > [ovs_cv_sphinx], > - [if sphinx-build --version >/dev/null 2>&1; then > + [if type sphinx-build >/dev/null 2>&1; then > ovs_cv_sphinx=yes > else > ovs_cv_sphinx=no _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev