On Mon, May 22, 2017 at 07:39:22PM +0800, [email protected] wrote:
> There are two computer node, each have one vm. And the two vms in
> indifferent vlan networks. The ping between the vms is not success.
>
> The reason is that, acl of to-localnet port or from-localnet port is
> signed to contrack. So the pair of icmp request and reply have different
> zone id in one ovs node. This makes the ct state not correct.
>
> This patch do the modification that localnet port do not use ct.
>
> Signed-off-by: wangqianyu <[email protected]>
This patch was word-wrapped, but I was able to deal with that.
I don't exactly understand the problem. Does conntrack not work at all
with packets that go to/from localnet ports? Or does it have something
to do with VLAN tags?
Please document the new flows in ovn-northd.8.xml.
Also, checkpatch reported the following:
ERROR: Improper whitespace around control block
#17 FILE: b/ovn/northd/ovn-northd.c:1355:
if(!strcmp(nbsp->type, "localnet")) {
ERROR: Improper whitespace around control block
#28 FILE: b/ovn/northd/ovn-northd.c:2637:
if(od->localnet_port) {
WARNING: Line length is >79-characters long
#32 FILE: b/ovn/northd/ovn-northd.c:2641:
ds_put_format(&match_in, "ip && inport == %s",
od->localnet_port->json_key);
WARNING: Line length is >79-characters long
#33 FILE: b/ovn/northd/ovn-northd.c:2642:
ds_put_format(&match_out, "ip && outport == %s",
od->localnet_port->json_key);
Thanks a lot for working on OVN!