Add schema and CLI support for health checks on logical switch ports by introducing a new health check table and linking it from logical switch ports. Implement corresponding ovn-nbctl commands to manage LSP health checks. Also extend service monitoring to support the logical-switch-port type.
Signed-off-by: Alexandra Rukomoinikova <[email protected]> --- v1 --> v2: corrected all the comments and made one service monitor bind to only one address --- ovn-nb.ovsschema | 28 ++- ovn-nb.xml | 53 ++++ ovn-sb.ovsschema | 7 +- ovn-sb.xml | 11 + tests/ovn-nbctl.at | 196 +++++++++++++++ utilities/ovn-nbctl.8.xml | 52 ++++ utilities/ovn-nbctl.c | 516 ++++++++++++++++++++++++++++++++++++-- 7 files changed, 842 insertions(+), 21 deletions(-) diff --git a/ovn-nb.ovsschema b/ovn-nb.ovsschema index 8c2c1d861..538b37456 100644 --- a/ovn-nb.ovsschema +++ b/ovn-nb.ovsschema @@ -1,7 +1,7 @@ { "name": "OVN_Northbound", - "version": "7.15.0", - "cksum": "4060410729 43708", + "version": "7.16.0", + "cksum": "3492890733 44939", "tables": { "NB_Global": { "columns": { @@ -179,6 +179,11 @@ "refType": "strong"}, "min": 0, "max": 1}}, + "health_checks": {"type": {"key": {"type": "uuid", + "refTable": "Logical_Switch_Port_Health_Check", + "refType": "strong"}, + "min": 0, + "max": "unlimited"}}, "external_ids": { "type": {"key": "string", "value": "string", "min": 0, "max": "unlimited"}}}, @@ -246,6 +251,25 @@ "min": 0, "max": "unlimited"}}}, "indexes": [["name"], ["id"]], "isRoot": true}, + "Logical_Switch_Port_Health_Check": { + "columns": { + "protocol": { + "type": {"key": {"type": "string", + "enum": ["set", ["tcp", "udp", "icmp"]]}, + "min": 0, "max": 1}}, + "src_ip": {"type": "string"}, + "port": {"type": {"key": {"type": "integer", + "minInteger": 0, + "maxInteger": 65535}}}, + "address": {"type": {"key": "string", + "min": 0, + "max": 1}}, + "options": { + "type": {"key": "string", + "value": "string", + "min": 0, + "max": "unlimited"}}}, + "isRoot": false}, "Forwarding_Group": { "columns": { "name": {"type": "string"}, diff --git a/ovn-nb.xml b/ovn-nb.xml index 1acbf202b..e60edbd8d 100644 --- a/ovn-nb.xml +++ b/ovn-nb.xml @@ -2136,6 +2136,11 @@ Please see the <ref table="Mirror"/> table. </column> + <column name="health_checks"> + Health checks configuration for this logical switch port. + Please see the <ref table="Logical_Switch_Port_Health_Check"/> table. + </column> + <column name="ha_chassis_group"> References a row in the OVN Northbound database's <ref table="HA_Chassis_Group" db="OVN_Northbound"/> table. @@ -2192,6 +2197,54 @@ </group> </table> + <table name="Logical_Switch_Port_Health_Check" + title="logical switch port health check"> + <p> + Each row represents health check configuration for logical switch port. + Health checks are used to monitor reachability and health of backend + endpoints associated with logical switch port. Health check can be + configured to use different protocols (TCP, UDP, or ICMP) to verify + availability of target IP addresses. + </p> + + <column name="protocol"> + Valid protocols are <code>tcp</code>, <code>udp</code>, or + <code>icmp</code>. For <code>tcp</code> and <code>udp</code> + protocols - destination port must be specified. + </column> + + <column name="src_ip"> + Source IP address used when sending health check probes. + </column> + + <column name="port"> + Destination port number for TCP and UDP health checks. + </column> + + <column name="address"> + IP address to monitor for the health check. + </column> + + <column name="options" key="interval" type='{"type": "integer"}'> + The interval, in seconds, between service monitor checks. + </column> + + <column name="options" key="timeout" type='{"type": "integer"}'> + The time, in seconds, after which the service monitor check times + out. + </column> + + <column name="options" key="success_count" type='{"type": "integer"}'> + The number of successful checks after which the service is + considered <code>online</code>. + </column> + + <column name="options" key="failure_count" type='{"type": "integer"}'> + The number of failure checks after which the service is considered + <code>offline</code>. + </column> + </table> + <table name="Forwarding_Group" title="forwarding group"> <p> Each row represents one forwarding group. diff --git a/ovn-sb.ovsschema b/ovn-sb.ovsschema index cf33933da..dd9e32f06 100644 --- a/ovn-sb.ovsschema +++ b/ovn-sb.ovsschema @@ -1,7 +1,7 @@ { "name": "OVN_Southbound", - "version": "21.7.0", - "cksum": "1383351379 36646", + "version": "21.8.0", + "cksum": "3491605797 36713", "tables": { "SB_Global": { "columns": { @@ -516,7 +516,8 @@ "type": {"type": {"key": { "type": "string", "enum": ["set", ["load-balancer", - "network-function"]]}, + "network-function", + "logical-switch-port"]]}, "min": 0, "max": 1}}, "ip": {"type": "string"}, "mac": {"type": "string"}, diff --git a/ovn-sb.xml b/ovn-sb.xml index 00bae26bf..0ec7d6094 100644 --- a/ovn-sb.xml +++ b/ovn-sb.xml @@ -5042,6 +5042,8 @@ tcp.flags = RST; icmp, and the health probe is done by injecting an icmp echo request packet into the <code>inport</code> of the Network_Function and then montoring the same packet coming out of the <code>outport</code>. + For <code>type</code> "logical-switch-port", supported protocols are + <code>tcp</code>, <code>udp</code> and <code>icmp</code>. </column> <column name="port"> @@ -5124,6 +5126,15 @@ tcp.flags = RST; the service and doesn't expect any reply. If it receives an ICMP reply, then it considers the service to be <code>offline</code>. </p> + + <p> + For ICMP service, <code>ovn-controller</code> sends an ICMP + Echo Request and expects an ICMP Echo Reply to consider service + to be <code>online</code>. If no reply is received or if an ICMP + error message is received, the service is considered + <code>offline</code>. + </p> + </column> </group> diff --git a/tests/ovn-nbctl.at b/tests/ovn-nbctl.at index dccf30758..177e097fb 100644 --- a/tests/ovn-nbctl.at +++ b/tests/ovn-nbctl.at @@ -3499,3 +3499,199 @@ AT_CHECK([ovn-nbctl --may-exist lsp-add-localnet-port ls ln_port net1], [1], [], check ovn-nbctl lsp-set-options ln_port network_name=net1 check ovn-nbctl --may-exist lsp-add-localnet-port ls ln_port net1 ]) + +dnl --------------------------------------------------------------------- + +AT_SETUP([ovn-nbctl - Logical Switch Port Health Check]) +OVN_NBCTL_TEST_START daemon + +# Create logical switch port +AT_CHECK([ovn-nbctl ls-add ls0]) +AT_CHECK([ovn-nbctl lsp-add ls0 lport0]) +AT_CHECK([ovn-nbctl lsp-set-addresses lport0 "00:11:22:33:44:55 192.168.1.10" "00:11:22:33:44:56 192.168.1.11"]) + +# Create IPV4 ICMP health check +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 192.168.0.255 192.168.1.10]) +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl +Logical Switch Port lport0: + Protocol : icmp + Source IP : 192.168.0.255 + Addresses : 192.168.1.10 +]) + +# Check hc attaching to logical switch port +hc_icmp_uuid=$(fetch_column nb:logical_switch_port_health_check _uuid src_ip="192.168.0.255") +check_column "$hc_icmp_uuid" nb:logical_switch_port health_checks + +# Create IPv4 TCP health check with the specified addresses +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.2 80 192.168.1.10]) +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl +Logical Switch Port lport0: + Protocol : tcp + Source IP : 10.0.0.2 + Port : 80 + Addresses : 192.168.1.10 + + Protocol : icmp + Source IP : 192.168.0.255 + Addresses : 192.168.1.10 +]) +hc_tcp_uuid=$(fetch_column nb:logical_switch_port_health_check _uuid src_ip="10.0.0.2") + +# Create UDP health check with the specified addresses +AT_CHECK([ovn-nbctl lsp-hc-add lport0 udp 10.0.0.3 53 192.168.1.11]) +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl +Logical Switch Port lport0: + Protocol : tcp + Source IP : 10.0.0.2 + Port : 80 + Addresses : 192.168.1.10 + + Protocol : udp + Source IP : 10.0.0.3 + Port : 53 + Addresses : 192.168.1.11 + + Protocol : icmp + Source IP : 192.168.0.255 + Addresses : 192.168.1.10 +]) +hc_udp_uuid=$(fetch_column nb:logical_switch_port_health_check _uuid src_ip="10.0.0.3") + +check_column "$hc_icmp_uuid $hc_tcp_uuid $hc_udp_uuid" nb:logical_switch_port health_checks + +AT_CHECK([ovn-nbctl lsp-hc-del lport0 $hc_icmp_uuid]) +# Check hcs detaching to logical switch port +check_column "$hc_tcp_uuid $hc_udp_uuid" nb:logical_switch_port health_checks + +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl +Logical Switch Port lport0: + Protocol : tcp + Source IP : 10.0.0.2 + Port : 80 + Addresses : 192.168.1.10 + + Protocol : udp + Source IP : 10.0.0.3 + Port : 53 + Addresses : 192.168.1.11 +]) + +AT_CHECK([ovn-nbctl lsp-hc-del lport0]) +check_row_count nb:Logical_Switch_Port_Health_Check 0 +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl]) + +# Check invalid protocol +AT_CHECK([ovn-nbctl lsp-hc-add lport0 stcp 10.0.0.1 50], [1], [], [stderr]) +AT_CHECK([grep "Type must be icmp, tcp or udp" stderr], [0], [ignore]) + +# Check invalid source IP +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp invalid_ip invalid_ip], [1], [], [stderr]) +AT_CHECK([grep "Not a valid IPv4 or IPv6 address" stderr], [0], [ignore]) + +# Check TCP/UDP non-valid destination port +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.1 70000], [1], [], [stderr]) +AT_CHECK([grep "port must in range 0...65535" stderr], [0], [ignore]) + +# Check IP address not configured on port +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 10.0.0.1 192.168.99.99], [1], [], [stderr]) +AT_CHECK([grep "Address 192.168.99.99 not configured on port" stderr], [0], [ignore]) + +AT_CHECK([ovn-nbctl lsp-hc-del lport0]) + +# Different source IP, same protocol, port and address - should be allowed +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.1 80 192.168.1.10]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.2 80 192.168.1.10], [0], [], [ignore]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.3 80 192.168.1.10], [0], [], [ignore]) + +# Same source IP, different ports, same protocol and address - should be allowed +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.1 81 192.168.1.10], [0], [], [ignore]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.1 82 192.168.1.10], [0], [], [ignore]) + +# Same source IP and port, different protocols, same address - should be allowed +AT_CHECK([ovn-nbctl lsp-hc-add lport0 udp 10.0.0.1 80 192.168.1.10], [0], [], [ignore]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 10.0.0.1 192.168.1.10], [0], [], [ignore]) + +# Check duplication +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.5 90 192.168.1.10]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 tcp 10.0.0.5 90 192.168.1.10], [1], [], [stderr]) +AT_CHECK([grep "Health check with address 192.168.1.10 already exists on port lport0" stderr], [0], [ignore]) + +# ICMP - same source IP, different addresses - should be allowed +AT_CHECK([ovn-nbctl lsp-hc-del lport0]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 10.0.0.9 192.168.1.10]) +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 10.0.0.9 192.168.1.11], [0], [], [ignore]) + +# ICMP - different source IP, same address - should be allowed +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 10.0.0.10 192.168.1.10], [0], [], [ignore]) + +# Check supported logical switch port type for monitoring +AT_CHECK([ovn-nbctl lsp-add ls0 lport1]) +AT_CHECK([ovn-nbctl lsp-set-type lport1 router]) +AT_CHECK([ovn-nbctl lsp-hc-add lport1 icmp 10.0.0.1 10.0.0.2], [1], [], [stderr]) +AT_CHECK([grep "Health check monitoring supported only for port with vif type" stderr], [0], [ignore]) + +AT_CHECK([ovn-nbctl lsp-hc-del lport0]) + +# Test IPv6 addresses support: icmp, tcp, udp +AT_CHECK([ovn-nbctl lsp-add ls0 lport3]) +AT_CHECK([ovn-nbctl lsp-set-addresses lport3 "00:11:22:33:44:57 2001:db8::1"]) +AT_CHECK([ovn-nbctl lsp-hc-add lport3 icmp 2001:db8::2 2001:db8::1]) +AT_CHECK([ovn-nbctl lsp-hc-add lport3 tcp 2001:db8::2 80 2001:db8::1]) +AT_CHECK([ovn-nbctl lsp-hc-add lport3 udp 2001:db8::2 53 2001:db8::1]) +AT_CHECK([ovn-nbctl lsp-hc-list lport3], [0], [dnl +Logical Switch Port lport3: + Protocol : icmp + Source IP : 2001:db8::2 + Addresses : 2001:db8::1 + + Protocol : tcp + Source IP : 2001:db8::2 + Port : 80 + Addresses : 2001:db8::1 + + Protocol : udp + Source IP : 2001:db8::2 + Port : 53 + Addresses : 2001:db8::1 +]) + +AT_CHECK([ovn-nbctl lsp-hc-del lport3]) + +# Duplicate IPv6 health check - should be disabled +AT_CHECK([ovn-nbctl lsp-hc-add lport3 icmp 2001:db8::2 2001:db8::1]) +AT_CHECK([ovn-nbctl lsp-hc-add lport3 icmp 2001:db8::2 2001:db8::1], [1], [], [stderr]) +AT_CHECK([grep "Health check with address 2001:db8::1 already exists on port lport3" stderr], [0], [ignore]) + +# Check options printing +AT_CHECK([ovn-nbctl lsp-hc-add lport0 icmp 10.0.0.4 192.168.1.10 192.168.1.11]) +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl +Logical Switch Port lport0: + Protocol : icmp + Source IP : 10.0.0.4 + Addresses : 192.168.1.10 +]) +hc_icmp_uuid=$(fetch_column nb:logical_switch_port_health_check _uuid src_ip="10.0.0.4") + +AT_CHECK([ovn-nbctl set logical_switch_port_health_check $hc_icmp_uuid options:interval=3]) +AT_CHECK([ovn-nbctl set logical_switch_port_health_check $hc_icmp_uuid options:timeout=30]) +AT_CHECK([ovn-nbctl set logical_switch_port_health_check $hc_icmp_uuid options:success_count=1]) +AT_CHECK([ovn-nbctl set logical_switch_port_health_check $hc_icmp_uuid options:failure_count=2]) + +AT_CHECK([ovn-nbctl lsp-hc-list lport0], [0], [dnl +Logical Switch Port lport0: + Protocol : icmp + Source IP : 10.0.0.4 + Addresses : 192.168.1.10 + Interval : 3 + Timeout : 30 + Success count : 1 + Failure count : 2 +]) + +AT_CHECK([ovn-nbctl lsp-hc-del lport0]) +AT_CHECK([ovn-nbctl lsp-hc-del lport3]) +check_row_count nb:Logical_Switch_Port_Health_Check 0 + +OVN_NBCTL_TEST_STOP "/terminating with signal 15/d" +AT_CLEANUP diff --git a/utilities/ovn-nbctl.8.xml b/utilities/ovn-nbctl.8.xml index 7df902944..c403fcfb6 100644 --- a/utilities/ovn-nbctl.8.xml +++ b/utilities/ovn-nbctl.8.xml @@ -1822,6 +1822,58 @@ </dd> </dl> + <h2>Health Check commands</h2> + <dl> + <dt><code>lsp-hc-add</code> <var>PORT</var> <var>PROTOCOL</var> + <var>SOURCE_IP</var> [<var>DST_PORT</var>] <var>ADDRESS</var></dt> + <dd> + <p> + Creates a new health check configuration for the logical switch port + <code>PORT</code> with the below mandatory arguments. + </p> + + <p> + <var>PROTOCOL</var> specifies the health check protocol - + <code>tcp</code>, <code>udp</code>, or <code>icmp</code>. + </p> + + <p> + <var>SOURCE_IP</var> specifies the source IP address used when + sending health check probes. + </p> + + <p> + <var>DST_PORT</var> specifies the destination port number for + <code>tcp</code> and <code>udp</code> health checks. This parameter + is ignored for <code>icmp</code> protocol. + </p> + + <p> + <var>ADDRESS</var> specifies the IP address to monitor. + </p> + + <p> + Additional health check options such as interval, timeout, + success count, and failure count can be configured separately. + </p> + </dd> + + <dt><code>lsp-hc-del</code> <var>PORT</var> [<var>HC_UUID</var>]</dt> + <dd> + <p> + Deletes health check configuration for the logical switch port + <code>PORT</code>. + </p> + </dd> + + <dt><code>lsp-hc-list</code> <var>PORT</var></dt> + <dd> + Lists all health check configurations for the logical switch port + <code>PORT</code>, including protocol, source IP, destination port, + monitored addresses, and current status. + </dd> + </dl> + <h2>Synchronization Commands</h2> <dl> diff --git a/utilities/ovn-nbctl.c b/utilities/ovn-nbctl.c index cdf6b578a..e58001148 100644 --- a/utilities/ovn-nbctl.c +++ b/utilities/ovn-nbctl.c @@ -66,6 +66,18 @@ string_ptr(char *ptr) return (ptr) ? ptr : s; } +static char *OVS_WARN_UNUSED_RESULT +parse_l4_port_range(const char *arg, uint16_t *port_p) +{ + int64_t port; + if (!ovs_scan(arg, "%"SCNd64, &port) + || port < 0 || port > UINT16_MAX) { + return xasprintf("%s: port must in range 0...65535", arg); + } + *port_p = port; + return NULL; +} + static void nbctl_add_base_prerequisites(struct ovsdb_idl *idl, enum nbctl_wait_type wait_type) @@ -544,6 +556,12 @@ MAC_Binding commands:\n\ Delete Static_MAC_Binding entry\n\ static-mac-binding-list List all Static_MAC_Binding entries\n\ \n\ +Logical Switch Port Health Check:\n\ + lsp-hc-add PORT PROTOCOL SOURCE_IP DST_PORT ADDRESS...\n\ + add health check monitoring for PORT\n\ + lsp-hc-del PORT HC_UUID delete health check monitoring for PORT\n\ + lsp-hc-list PORT print health check for PORT\n\ +\n\ %s\ %s\ \n\ @@ -1464,18 +1482,23 @@ nbctl_pre_lsp_set_addresses(struct ctl_context *ctx) &nbrec_logical_switch_port_col_dynamic_addresses); } -static char * +static bool lsp_contains_duplicate_ip(struct lport_addresses *laddrs1, struct lport_addresses *laddrs2, - const struct nbrec_logical_switch_port *lsp_test) + const struct nbrec_logical_switch_port *lsp_test, + char **error_str) { for (size_t i = 0; i < laddrs1->n_ipv4_addrs; i++) { for (size_t j = 0; j < laddrs2->n_ipv4_addrs; j++) { if (laddrs1->ipv4_addrs[i].addr == laddrs2->ipv4_addrs[j].addr) { - return xasprintf("duplicate IPv4 address '%s' found on " - "logical switch port '%s'", - laddrs1->ipv4_addrs[i].addr_s, - lsp_test->name); + if (error_str) { + *error_str = xasprintf("duplicate IPv4 address '%s' " + "found on logical switch " + "port '%s'", + laddrs1->ipv4_addrs[i].addr_s, + lsp_test->name); + } + return true; } } } @@ -1484,15 +1507,23 @@ lsp_contains_duplicate_ip(struct lport_addresses *laddrs1, for (size_t j = 0; j < laddrs2->n_ipv6_addrs; j++) { if (IN6_ARE_ADDR_EQUAL(&laddrs1->ipv6_addrs[i].addr, &laddrs2->ipv6_addrs[j].addr)) { - return xasprintf("duplicate IPv6 address '%s' found on " - "logical switch port '%s'", - laddrs1->ipv6_addrs[i].addr_s, - lsp_test->name); + if (error_str) { + *error_str = xasprintf("duplicate IPv6 address " + "'%s' found on logical " + "switch port '%s'", + laddrs1->ipv6_addrs[i].addr_s, + lsp_test->name); + } + return true; } } } - return NULL; + if (error_str) { + *error_str = NULL; + } + + return false; } static char * @@ -1500,12 +1531,13 @@ lsp_contains_duplicates(const struct nbrec_logical_switch *ls, const struct nbrec_logical_switch_port *lsp, const char *address) { + char *error = NULL; + char *sub_error = NULL; struct lport_addresses laddrs; if (!extract_lsp_addresses(address, &laddrs)) { return NULL; } - char *sub_error = NULL; for (size_t i = 0; i < ls->n_ports; i++) { struct nbrec_logical_switch_port *lsp_test = ls->ports[i]; if (lsp_test == lsp) { @@ -1518,10 +1550,11 @@ lsp_contains_duplicates(const struct nbrec_logical_switch *ls, addr = lsp_test->dynamic_addresses; } if (extract_lsp_addresses(addr, &laddrs_test)) { - sub_error = lsp_contains_duplicate_ip(&laddrs, &laddrs_test, - lsp_test); + bool has_duplicate = + lsp_contains_duplicate_ip(&laddrs, &laddrs_test, + lsp_test, &sub_error); destroy_lport_addresses(&laddrs_test); - if (sub_error) { + if (has_duplicate) { goto err_out; } } @@ -1529,7 +1562,6 @@ lsp_contains_duplicates(const struct nbrec_logical_switch *ls, } err_out: ; - char *error = NULL; if (sub_error) { error = xasprintf("Error on switch %s: %s", ls->name, sub_error); free(sub_error); @@ -8677,6 +8709,448 @@ nbctl_lsp_add_misc_port(struct ctl_context *ctx) shash_add(&nbctx->lsp_to_ls_map, lsp_name, ls); } +/* Logical Switch Port Health Check Functions. */ +enum health_check_protocol { + LSP_ICMP_HEALTH_CHECK, + LSP_TCP_HEALTH_CHECK, + LSP_UDP_HEALTH_CHECK, +}; + +static char * +lsp_health_check_parse_protocol(const char *type, + enum health_check_protocol *protocol) +{ + char *error = NULL; + + if (!strcmp(type, "icmp")) { + *protocol = LSP_ICMP_HEALTH_CHECK; + } else if (!strcmp(type, "tcp")) { + *protocol = LSP_TCP_HEALTH_CHECK; + } else if (!strcmp(type, "udp")) { + *protocol = LSP_UDP_HEALTH_CHECK; + } else { + error = xasprintf("%s: Type must be icmp, tcp or udp.", type); + } + + return error; +} + +static char * +lsp_health_check_parse_dst_port(struct ctl_context *ctx, + enum health_check_protocol protocol, + const char *protocol_str, + uint16_t *destination_port, + int *target_ip_index) +{ + char *error; + + switch (protocol) { + case LSP_TCP_HEALTH_CHECK: + case LSP_UDP_HEALTH_CHECK: + if (ctx->argc < 5) { + error = xasprintf("Destination port required for " + "%s health check.", protocol_str); + return error; + } + + error = parse_l4_port_range(ctx->argv[4], destination_port); + if (error) { + return error; + } + + *target_ip_index = 5; + break; + + case LSP_ICMP_HEALTH_CHECK: + *target_ip_index = 4; + break; + + default: + OVS_NOT_REACHED(); + } + + if (*target_ip_index == ctx->argc) { + error = xasprintf("No addresses specified for health checking."); + return error; + } + + return NULL; +} + +static bool +lsp_health_check_get_duplicate_record( + int64_t destination_port, const char *protocol_str, + const char *source_ip_str, const char *target_ip_str, + const struct nbrec_logical_switch_port *lsp) +{ + for (size_t i = 0; i < lsp->n_health_checks; i++) { + const struct nbrec_logical_switch_port_health_check *lsp_hc_p = + lsp->health_checks[i]; + + if (!strcmp(lsp_hc_p->src_ip, source_ip_str) && + !strcmp(lsp_hc_p->protocol, protocol_str)) { + + if (strcmp(protocol_str, "icmp") && + lsp_hc_p->port != destination_port) { + continue; + } + + if (strcmp(lsp_hc_p->address, target_ip_str) == 0) { + return true; + } + } + } + + return false; +} + +static char * +lsp_health_check_parse_target_address( + const char *target_ip_str, const char *protocol_str, + const char *source_ip_str, const int64_t destination_port, + const struct nbrec_logical_switch_port *lsp) +{ + bool ip_found_on_port = false; + char *error = NULL; + + struct lport_addresses target_address; + if (!extract_ip_address(target_ip_str, &target_address)) { + error = xasprintf("Not a valid IPv4 or IPv6 address %s.", + target_ip_str); + return error; + } + + struct lport_addresses lsp_address; + for (size_t i = 0; i < lsp->n_addresses; i++) { + if (!extract_lsp_addresses(lsp->addresses[i], &lsp_address)) { + error = xasprintf("Error extracting logical switch port address."); + goto cleanup; + } + + if (lsp_contains_duplicate_ip(&target_address, + &lsp_address, lsp, NULL)) { + ip_found_on_port = true; + } + + destroy_lport_addresses(&lsp_address); + + if (ip_found_on_port) { + break; + } + } + + if (!ip_found_on_port) { + error = xasprintf("Address %s not configured on port %s.", + target_ip_str, lsp->name); + goto cleanup; + } + + if (lsp_health_check_get_duplicate_record(destination_port, + protocol_str, + source_ip_str, + target_ip_str, lsp)) { + error = xasprintf("Health check with address %s already exists " + "on port %s.", target_ip_str, lsp->name); + goto cleanup; + } + +cleanup: + destroy_lport_addresses(&target_address); + return error; +} + +static void +nbctl_pre_lsp_health_check_add(struct ctl_context *ctx) +{ + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_name); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_addresses); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_health_checks); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_port); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_protocol); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_src_ip); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_address); +} + +static void +nbctl_lsp_health_check_add(struct ctl_context *ctx) +{ + const struct nbrec_logical_switch_port *lsp = NULL; + const struct nbrec_logical_switch_port_health_check *lsp_hc = NULL; + + const char *lsp_port_name = ctx->argv[1]; + const char *protocol_type = ctx->argv[2]; + const char *src_ip = ctx->argv[3]; + char *error = NULL; + + error = lsp_by_name_or_uuid(ctx, lsp_port_name, true, &lsp); + if (error) { + ctx->error = error; + return; + } + + if (lsp->type && lsp->type[0]) { + ctl_error(ctx, "%s: Health check monitoring supported only for" + " port with vif type.", lsp->type); + return; + } + + char *validated_src_ip = normalize_addr_str(src_ip); + if (!validated_src_ip) { + ctl_error(ctx, "%s: Not a valid IPv4 or IPv6 address.", src_ip); + goto cleanup; + } + + enum health_check_protocol protocol; + error = lsp_health_check_parse_protocol(protocol_type, &protocol); + if (error) { + ctx->error = error; + goto cleanup; + } + + uint16_t destination_port = 0; + int target_ip_index = 0; + error = lsp_health_check_parse_dst_port(ctx, protocol, + protocol_type, + &destination_port, + &target_ip_index); + if (error) { + ctx->error = error; + goto cleanup; + } + + const char *target_address = ctx->argv[target_ip_index]; + error = lsp_health_check_parse_target_address( + target_address, protocol_type, + validated_src_ip, destination_port, lsp); + if (error) { + ctx->error = error; + goto cleanup; + } + + lsp_hc = nbrec_logical_switch_port_health_check_insert(ctx->txn); + nbrec_logical_switch_port_health_check_set_protocol(lsp_hc, + protocol_type); + nbrec_logical_switch_port_health_check_set_src_ip(lsp_hc, + validated_src_ip); + nbrec_logical_switch_port_health_check_set_port(lsp_hc, + destination_port); + + nbrec_logical_switch_port_health_check_set_address(lsp_hc, + target_address); + + nbrec_logical_switch_port_update_health_checks_addvalue(lsp, lsp_hc); + +cleanup: + free(validated_src_ip); +} + +static char * OVS_WARN_UNUSED_RESULT +find_logical_switch_port_health_check_by_uuid( + struct ctl_context *ctx, + const char *id, + const struct nbrec_logical_switch_port_health_check **lsp_hc_p) +{ + const struct nbrec_logical_switch_port_health_check *lsp_hc; + *lsp_hc_p = NULL; + + struct uuid lsp_hc_uuid; + bool is_uuid = uuid_from_string(&lsp_hc_uuid, id); + + if (!is_uuid) { + return xasprintf("%s: Invalid UUID format.", id); + } + + lsp_hc = nbrec_logical_switch_port_health_check_get_for_uuid( + ctx->idl, &lsp_hc_uuid); + + if (!lsp_hc) { + return xasprintf("%s: Logical Switch Port Health Check " + "not found.", id); + } + + *lsp_hc_p = lsp_hc; + + return NULL; +} + +static void +nbctl_pre_lsp_health_check_del(struct ctl_context *ctx) +{ + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_name); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_health_checks); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_protocol); +} + +static void +nbctl_lsp_health_check_del(struct ctl_context *ctx) +{ + const struct nbrec_logical_switch_port_health_check *lsp_hc = NULL; + const struct nbrec_logical_switch_port *lsp = NULL; + const char *port_id = ctx->argv[1]; + const char *hc_uuid = ctx->argv[2]; + + char *error; + error = lsp_by_name_or_uuid(ctx, port_id, true, &lsp); + if (error) { + ctx->error = error; + return; + } + + if (hc_uuid) { + error = find_logical_switch_port_health_check_by_uuid(ctx, + hc_uuid, + &lsp_hc); + if (error) { + ctx->error = error; + return; + } + + nbrec_logical_switch_port_update_health_checks_delvalue(lsp, lsp_hc); + nbrec_logical_switch_port_health_check_delete(lsp_hc); + return; + } + + for (size_t i = 0; i < lsp->n_health_checks; i++) { + nbrec_logical_switch_port_update_health_checks_delvalue( + lsp, lsp->health_checks[i]); + nbrec_logical_switch_port_health_check_delete(lsp->health_checks[i]); + } +} + +static int +lsp_health_check_cmp(const void *lsp_hc_1_, const void *lsp_hc_2_) +{ + const struct nbrec_logical_switch_port_health_check *const *lsp_hc_1p = + lsp_hc_1_; + const struct nbrec_logical_switch_port_health_check *const *lsp_hc_2p = + lsp_hc_2_; + const struct nbrec_logical_switch_port_health_check *lsp_hc_1 = + *lsp_hc_1p; + const struct nbrec_logical_switch_port_health_check *lsp_hc_2 = + *lsp_hc_2p; + + int src_ip_cmp = strcmp(lsp_hc_1->src_ip, lsp_hc_2->src_ip); + if (src_ip_cmp) { + return src_ip_cmp; + } + + int protocol_cmp = strcmp(lsp_hc_1->protocol, lsp_hc_2->protocol); + if (protocol_cmp) { + return protocol_cmp; + } + + if (strcmp(lsp_hc_1->protocol, "icmp")) { + if (lsp_hc_1->port != lsp_hc_2->port) { + return lsp_hc_1->port < lsp_hc_2->port ? -1 : 1; + } + } + + int ip_cmp = strcmp(lsp_hc_1->address, lsp_hc_2->address); + if (ip_cmp) { + return ip_cmp; + } + + return 0; +} + +static void +nbctl_pre_lsp_health_check_list(struct ctl_context *ctx) +{ + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_name); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_col_health_checks); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_port); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_protocol); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_src_ip); + ovsdb_idl_add_column(ctx->idl, + &nbrec_logical_switch_port_health_check_col_address); +} + +static void +nbctl_lsp_health_check_list(struct ctl_context *ctx) +{ + const struct nbrec_logical_switch_port_health_check **lsp_hcs; + const struct nbrec_logical_switch_port *lsp = NULL; + const char *port = ctx->argv[1]; + + char *error; + error = lsp_by_name_or_uuid(ctx, port, true, &lsp); + if (error) { + ctx->error = error; + return; + } + + if (!lsp->n_health_checks) { + return; + } + + lsp_hcs = xmalloc(sizeof *lsp_hcs * lsp->n_health_checks); + for (size_t i = 0; i < lsp->n_health_checks; i++) { + lsp_hcs[i] = lsp->health_checks[i]; + } + + qsort(lsp_hcs, lsp->n_health_checks, + sizeof *lsp_hcs, lsp_health_check_cmp); + + ds_put_format(&ctx->output, "Logical Switch Port %s:\n", port); + for (size_t i = 0; i < lsp->n_health_checks; i++) { + const struct nbrec_logical_switch_port_health_check *hc + + = lsp_hcs[i]; + ds_put_format(&ctx->output, " Protocol : %s\n", + hc->protocol); + ds_put_format(&ctx->output, " Source IP : %s\n", + hc->src_ip); + + if (strcmp(hc->protocol, "icmp")) { + ds_put_format(&ctx->output, " Port : %"PRId64"\n", + hc->port); + } + + ds_put_format(&ctx->output, " Addresses : "); + ds_put_format(&ctx->output, "%s", hc->address); + ds_put_format(&ctx->output, "\n"); + + int interval = smap_get_int(&hc->options, "interval", 0); + int timeout = smap_get_int(&hc->options, "timeout", 0); + int success_count = smap_get_int(&hc->options, "success_count", 0); + int failure_count = smap_get_int(&hc->options, "failure_count", 0); + if (interval) { + ds_put_format(&ctx->output, " Interval : %d\n", + interval); + } + if (timeout) { + ds_put_format(&ctx->output, " Timeout : %d\n", + timeout); + } + if (success_count) { + ds_put_format(&ctx->output, " Success count : %d\n", + success_count); + } + if (failure_count) { + ds_put_format(&ctx->output, " Failure count : %d\n", + failure_count); + } + if (i < lsp->n_health_checks - 1) { + ds_put_format(&ctx->output, "\n"); + } + } +} + static const struct ctl_table_class tables[NBREC_N_TABLES] = { [NBREC_TABLE_DHCP_OPTIONS].row_ids = {{&nbrec_logical_switch_port_col_name, NULL, @@ -9064,6 +9538,16 @@ static const struct ctl_command_syntax nbctl_commands[] = { nbctl_pre_static_mac_binding, nbctl_static_mac_binding_list, NULL, "", RO }, + /* Health Check commands */ + {"lsp-hc-add", 4, 5, "PORT TYPE SRC_IP [DST_PORT] ADDRESS", + nbctl_pre_lsp_health_check_add, nbctl_lsp_health_check_add, + NULL, "", RW }, + {"lsp-hc-del", 1, INT_MAX, "PORT [HC_UUID]", + nbctl_pre_lsp_health_check_del, nbctl_lsp_health_check_del, + NULL, "", RW }, + {"lsp-hc-list", 1, 1, "PORT", nbctl_pre_lsp_health_check_list, + nbctl_lsp_health_check_list, NULL, "", RW }, + {NULL, 0, 0, NULL, NULL, NULL, NULL, "", RO}, }; -- 2.48.1 _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev