Thanks for the new file in this version!

Acked-by: Mark Michelson <[email protected]>

On Wed, Aug 12, 2026 at 6:26 PM Rosemarie O'Riorden via dev
<[email protected]> wrote:
>
> Reported-at: https://redhat.atlassian.net/browse/FDP-3051
> Assisted-by: Claude Opus 4.6, Claude Code
> Signed-off-by: Rosemarie O'Riorden <[email protected]>
> ---
> v3:
>  - Added this commit to address this part of the ticket.
> ---
>  .../vif-plug-providers/vif-plug-providers.rst | 37 +++++++++++--------
>  1 file changed, 21 insertions(+), 16 deletions(-)
>
> diff --git a/Documentation/topics/vif-plug-providers/vif-plug-providers.rst 
> b/Documentation/topics/vif-plug-providers/vif-plug-providers.rst
> index 77ecf7e0f..8b08b4e91 100644
> --- a/Documentation/topics/vif-plug-providers/vif-plug-providers.rst
> +++ b/Documentation/topics/vif-plug-providers/vif-plug-providers.rst
> @@ -25,10 +25,10 @@
>  VIF Plug Providers
>  ==================
>
> -Traditionally it has been the CMSes responsibility to create VIFs as part of
> +Traditionally it has been the CMS's responsibility to create VIFs as part of
>  instance life cycle, and subsequently manage plug/unplug operations on the
>  integration bridge following the conventions described in the
> -`Open vSwitch Integration Guide`_ for mapping of VIFs to OVN logical port.
> +`Open vSwitch Integration Guide`_ for mapping of VIFs to OVN logical ports.
>
>  With the advent of NICs connected to multiple distinct CPUs we can have a
>  topology where the instance runs on one host and Open vSwitch and OVN runs on
> @@ -44,7 +44,7 @@ the plugging, we provide a pluggable infrastructure in OVN 
> that allows the
>  `ovn-controller` to perform the plugging on CMS direction.
>
>  Hardware or platform specific details for initialization and lookup of
> -representor ports is provided by an plugging provider library hosted inside 
> or
> +representor ports is provided by a plugging provider library hosted inside or
>  outside the core OVN repository, and linked at OVN build time.
>
>  Life Cycle of an OVN plugged VIF
> @@ -70,10 +70,11 @@ Life Cycle of an OVN plugged VIF
>     exists yet.
>
>  4. It will fill the `struct vif_plug_port_ctx_in` as defined in
> -   `lib/vif-plug.h` with `op_type` set to 'PLUG_OP_CREATE' and make a call to
> -   the VIF plug providers `vif_plug_port_prepare` callback function.  VIF 
> plug
> -   provider performs lookup and fills the `struct vif_plug_port_ctx_out` as
> -   defined in `lib/vif-plug.h`.
> +   `lib/vif-plug-provider.h` with `op_type` set to 'PLUG_OP_CREATE' and
> +   make a call to the VIF plug providers `vif_plug_port_prepare` callback
> +   function.  VIF plug provider performs lookup and fills the
> +   `struct vif_plug_port_ctx_out` as defined in
> +   `lib/vif-plug-provider.h`.
>
>  5. `ovn-controller` creates a port and interface record in the local OVSDB
>     using the details provided by the VIF plug provider and also adds
> @@ -84,7 +85,7 @@ Life Cycle of an OVN plugged VIF
>     `vif_plug_port_ctx_destroy` function to free any memory allocated by the 
> VIF
>     plug implementation.
>
> -6. The Open vSwitch vswitchd will assign a ofport to the newly created
> +6. The Open vSwitch vswitchd will assign an ofport to the newly created
>     interface and on the next `ovn-controller` main loop iteration flows will 
> be
>     installed.
>
> @@ -115,9 +116,11 @@ will be registered by the identifier provided in the 
> `const char *type`
>  pointer, at this time the `init` function pointer will be called if it is
>  non-NULL.
>
> -> **Note**: apart from the `const char *type` pointer, no attempt will be 
> made
> -            to access VIF plug provider data or functions before the call to
> -            the `init` has been made.
> +.. note::
> +
> +   Apart from the ``const char *type`` pointer, no attempt will be made
> +   to access VIF plug provider data or functions before the call to
> +   the ``init`` has been made.
>
>  On `ovn-controller` exit, the VIF plug providers registered in the above
>  mentioned procedure will have their `destroy` function pointer called if it 
> is
> @@ -143,17 +146,19 @@ Before creating or updating an existing interface 
> record the VIF plug provider
>  structures.  If the VIF plug provider implementation is able to perform 
> lookup
>  it should fill the `struct vif_plug_port_ctx_out` data structure and return
>  'true'.  The `ovn-controller` will then create or update the port/interface
> -records and then call `vif_plug_port_finish` when the transactions commits 
> and
> +records and then call `vif_plug_port_finish` when the transaction commits and
>  `vif_plug_port_ctx_destroy` to free any allocated memory.  If the VIF plug
>  provider implementation is unable to perform lookup or prepare the desired
>  resource at this time, it should return 'false' which will tell the
>  `ovn-controller` to not plug the port, in this case it will not call
>  `vif_plug_port_finish` nor `vif_plug_port_ctx_destroy`.
>
> -> **Note**: The VIF plug provider implementation should exhaust all
> -            non-blocking options to succeed with lookup from within the
> -            `vif_plug_port_prepare` handler, including refreshing lookup
> -            tables if necessary.
> +.. note::
> +
> +   The VIF plug provider implementation should exhaust all
> +   non-blocking options to succeed with lookup from within the
> +   ``vif_plug_port_prepare`` handler, including refreshing lookup
> +   tables if necessary.
>
>  Before removing port and interface records previously plugged by the
>  `ovn-controller` as identified by presence of the Interface
> --
> 2.55.0
>
> _______________________________________________
> dev mailing list
> [email protected]
> https://mail.openvswitch.org/mailman/listinfo/ovs-dev
>

_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev

Reply via email to