This patch adds support for a "requested-chassis" option for logical switch ports. If set, the only chassis that will claim this port is the chassis identfied by this option; if already bound by another chassis, it will be released.
The primary benefit of this enhancement is allowing a CMS to prevent "thrashing" in the southbound database during live migration by keeping the original chassis from attempting to re-bind a port that is in the process of migrating. This would also allow (with some additional work) RBAC to be applied to the Port_Binding table for additional security. Signed-off-by: Lance Richardson <[email protected]> --- v2: Added documentation text suggested by Russell Bryant. ovn/controller/binding.c | 15 +++++++++++- ovn/ovn-nb.xml | 8 +++++++ ovn/ovn-sb.xml | 8 +++++++ tests/ovn.at | 59 ++++++++++++++++++++++++++++++++++++++++++++++++ 4 files changed, 89 insertions(+), 1 deletion(-) diff --git a/ovn/controller/binding.c b/ovn/controller/binding.c index 32309e9e3..6a56e26ca 100644 --- a/ovn/controller/binding.c +++ b/ovn/controller/binding.c @@ -440,7 +440,12 @@ consider_local_datapath(struct controller_ctx *ctx, } if (ctx->ovnsb_idl_txn) { - if (our_chassis) { + const char *vif_chassis = smap_get(&binding_rec->options, + "requested-chassis"); + bool can_bind = !vif_chassis || !vif_chassis[0] || + !strcmp(vif_chassis, chassis_rec->name); + + if (can_bind && our_chassis) { if (binding_rec->chassis != chassis_rec) { if (binding_rec->chassis) { VLOG_INFO("Changing chassis for lport %s from %s to %s.", @@ -461,6 +466,14 @@ consider_local_datapath(struct controller_ctx *ctx, VLOG_INFO("Releasing lport %s from this chassis.", binding_rec->logical_port); sbrec_port_binding_set_chassis(binding_rec, NULL); + } else if (our_chassis) { + static struct vlog_rate_limit rl = VLOG_RATE_LIMIT_INIT(5, 1); + VLOG_INFO_RL(&rl, + "Not claiming lport %s, chassis %s " + "requested-chassis %s", + binding_rec->logical_port, + chassis_rec->name, + vif_chassis); } } } diff --git a/ovn/ovn-nb.xml b/ovn/ovn-nb.xml index 31303a846..be72610c0 100644 --- a/ovn/ovn-nb.xml +++ b/ovn/ovn-nb.xml @@ -435,6 +435,14 @@ (empty string) </p> + <column name="options" key="requested-chassis"> + If set, identifies a specific chassis (by name) that is allowed to + bind this port. Using this option will prevent thrashing between + two chassis trying to bind the same port during a live migration. + It can also prevent similar thrashing due to a mis-configuration, + if a port is accidentally created on more than one chassis. + </column> + <column name="options" key="qos_max_rate"> If set, indicates the maximum rate for data sent from this interface, in bit/s. The traffic will be shaped according to this limit. diff --git a/ovn/ovn-sb.xml b/ovn/ovn-sb.xml index 08d784ac6..7098194c6 100644 --- a/ovn/ovn-sb.xml +++ b/ovn/ovn-sb.xml @@ -2159,6 +2159,14 @@ tcp.flags = RST; (empty string) </p> + <column name="options" key="requested-chassis"> + If set, identifies a specific chassis (by name) that is allowed to + bind this port. Using this option will prevent thrashing between + two chassis trying to bind the same port during a live migration. + It can also prevent similar thrashing due to a mis-configuration, + if a port is accidentally created on more than one chassis. + </column> + <column name="options" key="qos_max_rate"> If set, indicates the maximum rate for data sent from this interface, in bit/s. The traffic will be shaped according to this limit. diff --git a/tests/ovn.at b/tests/ovn.at index 7d816785e..dcd0cf1a1 100644 --- a/tests/ovn.at +++ b/tests/ovn.at @@ -8281,3 +8281,62 @@ AT_CHECK([grep "Releasing lport" gw1/ovn-controller.log], [1], []) OVN_CLEANUP([gw1],[gw2],[hv1]) AT_CLEANUP + +AT_SETUP([ovn -- options:requested-chassis for logical port]) +ovn_start + +net_add n1 + +ovn-nbctl ls-add ls0 +ovn-nbctl lsp-add ls0 lsp0 + +# create two hypervisors, each with one vif port +sim_add hv1 +as hv1 +ovs-vsctl add-br br-phys +ovn_attach n1 br-phys 192.168.0.11 +ovs-vsctl -- add-port br-int hv1-vif0 + +sim_add hv2 +as hv2 +ovs-vsctl add-br br-phys +ovn_attach n1 br-phys 192.168.0.12 +ovs-vsctl -- add-port br-int hv2-vif0 + +# Allow only chassis hv1 to bind logical port lsp0. +ovn-nbctl lsp-set-options lsp0 requested-chassis=hv1 + +# Allow some time for ovn-northd and ovn-controller to catch up. +ovn-nbctl --wait=hv --timeout=3 sync + +# Retrieve hv1 and hv2 chassis UUIDs from southbound database +hv1_uuid=$(ovn-sbctl --bare --columns _uuid find chassis name=hv1) +hv2_uuid=$(ovn-sbctl --bare --columns _uuid find chassis name=hv2) + +# (1) Chassis hv2 should not bind lsp0 when requested-chassis is hv1. +echo "verifying that hv2 does not bind lsp0 when hv2 physical/logical mapping is added" +as hv2 +ovs-vsctl set interface hv2-vif0 external-ids:iface-id=lsp0 + +OVS_WAIT_UNTIL([test 1 = $(grep -c "Not claiming lport lsp0" hv2/ovn-controller.log)]) +AT_CHECK([test x$(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = x], [0], []) + +# (2) Chassis hv1 should bind lsp0 when physical to logical mapping exists on hv1. +echo "verifying that hv1 binds lsp0 when hv1 physical/logical mapping is added" +as hv1 +ovs-vsctl set interface hv1-vif0 external-ids:iface-id=lsp0 + +OVS_WAIT_UNTIL([test 1 = $(grep -c "Claiming lport lsp0" hv1/ovn-controller.log)]) +AT_CHECK([test $(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = "$hv1_uuid"], [0], []) + +# (3) Chassis hv1 should release lsp0 binding and chassis hv2 should bind lsp0 when +# the requested chassis for lsp0 is changed from hv1 to hv2. +echo "verifying that lsp0 binding moves when requested-chassis is changed" + +ovn-nbctl lsp-set-options lsp0 requested-chassis=hv2 +OVS_WAIT_UNTIL([test 1 = $(grep -c "Releasing lport lsp0 from this chassis" hv1/ovn-controller.log)]) +OVS_WAIT_UNTIL([test $(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = "$hv2_uuid"]) + +OVN_CLEANUP([hv1],[hv2]) + +AT_CLEANUP -- 2.13.4 _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev