On 19.12.2017 14:56, Jan Scheurich wrote: > I am OK with Ilya's proposal. > > The only correction I need to make is that for us 50 us showed good > improvements in a "PVP" scenario with iperf3 as kernel application in the > guest (not VM-VM).
OK. Thanks. I'll send this version with above correction as a proper [PATCH] soon. Jan, I also would like to add you as a co-author if you don't mind. Best regards, Ilya Maximets. > > BR, Jan > >> -----Original Message----- >> From: Stokes, Ian [mailto:[email protected]] >> Sent: Tuesday, 19 December, 2017 12:40 >> To: Ilya Maximets <[email protected]>; Jan Scheurich >> <[email protected]>; [email protected]; Bodireddy, >> Bhanuprakash <[email protected]> >> Cc: Heetae Ahn <[email protected]>; Fischetti, Antonio >> <[email protected]>; Eelco Chaudron >> <[email protected]>; Loftus, Ciara <[email protected]>; Kevin Traynor >> <[email protected]> >> Subject: RE: [RFC v2] docs: Describe output packet batching in DPDK guide. >> >>> On 19.12.2017 13:39, Stokes, Ian wrote: >>>>> Hi Ilya, >>>>> >>>>> Some more suggestions below to expand a bit on the use cases for >>>>> tx-flush- interval. >>>>> >>>>> BR, Jan >>>> >>>> Hi Ilya, >>>> >>>> I agree with Jans input here. I've finished validating the output >>> batching patchset today bit would like to include this documentation also. >>>> >>>> Are you planning to re-spin a new version of this patch with the >>> required changes? >>> >>> I have concerns about suggesting exact value of 50 microseconds or even >>> saying that increasing of 'tx-flush-interval' will increase performance >>> without stating the exact testing scenario and environment including >>> hardware. >> >> Sure, from case to case this could vary. >>> >>> Testing shows that optimal value of 'tx-flush-interval' highly depends on >>> scenario and possible traffic patterns. For example, tx-flush-interval=50 >>> significantly degrades performance of PVP with bonded HW NICs scenario on >>> x86. >>> I didn't finish the full testing, but it also degrades performance of VM- >>> VM scenario with Linux kernel guests (interrupt based) on my ARMv8 system. >>> >>> So, I prefer to avoid saying that this value will increase performance. At >>> least without full testing scenario description. >> >> Sure, I think over time as more testing of different scenarios is completed >> we can add to this. >> >> It probably makes sense to give just a general comment for people getting >> started with the caveat that users need to experiment to tune >> for their own needs in specific deployments. >> >>> >>> I'll try to modify Jan's comments according to above concerns. >>> >>> What about something like this: >>> ---------------------- >>> To make advantage of batched transmit functions, OVS collects packets in >>> intermediate queues before sending when processing a batch of received >>> packets. >>> Even if packets are matched by different flows, OVS uses a single send >>> operation for all packets destined to the same output port. >>> >>> Furthermore, OVS is able to buffer packets in these intermediate queues >>> for a configurable amount of time to reduce the frequency of send bursts >>> at medium load levels when the packet receive rate is high, but the >>> receive batch size still very small. This is particularly beneficial for >>> packets transmitted to VMs using an interrupt-driven virtio driver, where >>> the interrupt overhead is significant for the OVS PMD, the host operating >>> system and the guest driver. >>> >>> The ``tx-flush-interval`` parameter can be used to specify the time in >>> microseconds OVS should wait between two send bursts to a given port >>> (default is ``0``). When the intermediate queue fills up before that time >>> is over, the buffered packet batch is sent immediately:: >>> >>> $ ovs-vsctl set Open_vSwitch . other_config:tx-flush-interval=50 >>> >>> This parameter influences both throughput and latency, depending on the >>> traffic load on the port. In general lower values decrease latency while >>> higher values may be useful to achieve higher throughput. >>> >>> Low traffic (``packet rate < 1 / tx-flush-interval``) should not >>> experience any significant latency or throughput increase as packets are >>> forwarded immediately. >>> >>> At intermediate load levels >>> (``1 / tx-flush-interval < packet rate < 32 / tx-flush-interval``) traffic >>> should experience an average latency increase of up to >>> ``1 / 2 * tx-flush-interval`` and a possible throughput improvement. >>> >>> Very high traffic (``packet rate >> 32 / tx-flush-interval``) should >>> experience the average latency increase equal to ``32 / (2 * packet >>> rate)``. Most send batches in this case will contain the maximum number of >>> packets (``32``). >>> >>> A ``tx-burst-interval`` value of ``50`` microseconds has shown to provide >>> a good performance increase in a ``VM-VM`` scenario on x86 system for >>> interrupt-driven guests while keeping the latency increase at a reasonable >>> level. >>> >>> .. note:: >>> Throughput impact of this option significantly depends on the scenario >>> and >>> the traffic patterns. For example: ``tx-burst-interval`` value of ``50`` >>> microseconds shows performance degradation in PVP with bonded PHY >>> scenario >>> while testing with ``256 - 1024`` packet flows: >>> >>> https://mail.openvswitch.org/pipermail/ovs-dev/2017- >>> December/341700.html >>> >> >> Over all I think above looks good. We'll never be able to detail every test >> scenario but this gets the general trade off across to a user of >> latency/throughput in relation to the timing parameter. >> >> I'd be happy to take something like above for the initial merge and it could >> be expanded upon as people test going forward. >> >> Ian >> >>> ---------------------- >>> >>> >>>> >>>> Thanks >>>> Ian >>>>> >>>>>> -----Original Message----- >>>>>> From: Ilya Maximets [mailto:[email protected]] >>>>>> Sent: Tuesday, 12 December, 2017 14:07 >>>>>> To: [email protected]; Bhanuprakash Bodireddy >>>>>> <[email protected]> >>>>>> Cc: Heetae Ahn <[email protected]>; Antonio Fischetti >>>>>> <[email protected]>; Eelco Chaudron <[email protected]>; >>>>>> Ciara Loftus <[email protected]>; Kevin Traynor >>>>>> <[email protected]>; Jan Scheurich <[email protected]>; >>>>>> Ian Stokes <[email protected]>; Ilya Maximets >>>>>> <[email protected]> >>>>>> Subject: [RFC v2] docs: Describe output packet batching in DPDK guide. >>>>>> >>>>>> Added information about output packet batching and a way to >>>>>> configure 'tx-flush-interval'. >>>>>> >>>>>> Signed-off-by: Ilya Maximets <[email protected]> >>>>>> --- >>>>>> >>>>>> Version 2: >>>>>> * Some grammar/wording corrections. (Eelco Chaudron) >>>>>> >>>>>> Documentation/intro/install/dpdk.rst | 24 ++++++++++++++++++++++++ >>>>>> 1 file changed, 24 insertions(+) >>>>>> >>>>>> diff --git a/Documentation/intro/install/dpdk.rst >>>>>> b/Documentation/intro/install/dpdk.rst >>>>>> index 3fecb5c..5485dbc 100644 >>>>>> --- a/Documentation/intro/install/dpdk.rst >>>>>> +++ b/Documentation/intro/install/dpdk.rst >>>>>> @@ -568,6 +568,30 @@ not needed i.e. jumbo frames are not needed, it >>>>>> can be forced off by adding chains of descriptors it will make more >>>>>> individual virtio descriptors available for rx to the guest using >>>>> dpdkvhost ports and this can improve performance. >>>>>> >>>>>> +Output Packet Batching >>>>>> +~~~~~~~~~~~~~~~~~~~~~~ >>>>>> + >>>>>> +To get advantages of the batched send functions OVS collects >>>>>> +packets in intermediate queues before sending. This allows using a >>>>>> +single send for packets matched by different flows but having the >>>>>> +same output >>>>> action. >>>>>> +Furthermore, OVS is able to collect packets for some reasonable >>>>>> +amount of time before batch sending them which might help when >>>>>> +input >>>>> batches are small. >>>>> >>>>> To make advantage of batched transmit functions, OVS collects packets >>>>> in intermediate queues before sending when processing a batch of >>>>> received packets. Even if packets are matched by different flows, OVS >>>>> uses a single send operation for all packets destined to the same >>> output port. >>>>> >>>>> Furthermore, OVS is able to buffer packets in these intermediate >>>>> queues for a configurable amount of time to reduce the frequency of >>>>> send bursts at medium load levels when the packet receive rate is >>>>> high, but the receive batch size still very small. This is >>>>> particularly beneficial for packets transmitted to VMs using an >>>>> interrupt-driven virtio driver, where the interrupt overhead is >>>>> significant for the OVS PMD, the host operating system and the guest >>> driver. >>>>> >>>>>> + >>>>>> +``tx-flush-interval`` config could be used to specify the time in >>>>>> +microseconds that a packet can wait in an output queue for sending >>>>> (default is ``0``):: >>>>> >>>>> The ``tx-flush-interval`` parameter can be used to specify the time >>>>> in microseconds OVS should wait between two send bursts to a given >>>>> port (default is ``0``). When the intermediate queue fills up before >>>>> that time is over, the buffered packet batch is sent immediately:: >>>>> >>>>>> + >>>>>> + $ ovs-vsctl set Open_vSwitch . >>>>>> + other_config:tx-flush-interval=50 >>>>>> + >>>>>> +Lower values decrease latency while higher values may be useful to >>>>>> +achieve higher performance. For example, increasing of >>>>>> +``tx-flush-interval`` can be used to decrease the number of >>>>>> +interrupts >>>>> for interrupt based guest drivers. >>>>>> +This may significantly affect the performance. Zero value means >>>>>> +immediate send at the end of processing a single input batch. >>>>> >>>>> This parameter influences both throughput and latency, depending on >>>>> the traffic load on the port. In general lower values decrease >>>>> latency while higher values may be useful to achieve higher throughput. >>>>> >>>>> Low traffic (packet rate < 1/tx-flush-interval) should not experience >>>>> any significant latency or throughput increase as packets are >>>>> forwarded immediately. >>>>> >>>>> At intermediate load levels (1/tx-flush-interval < packet rate < >>>>> 32/tx- >>>>> flush-interval) traffic should experience an average latency increase >>>>> of up to 1/2 * tx-flush-interval and a throughput improvement that >>>>> depends on the average size of send bursts and grows with the traffic >>> rate. >>>>> >>>>> Very high traffic (packet rate >> 32/tx-flush-interval) should >>>>> experience improved throughput as most send batches contain the >>>>> maximum number of packets (32). The average latency increase should >>>>> equal 32/(2 * packet rate). >>>>> >>>>> A tx-burst-interval value of 50 microseconds has shown to provide a >>>>> good performance increase for interrupt-driven guests while keeping >>>>> the latency increase at a reasonable level. >>>>> >>>>>> + >>>>>> +Average number of packets per output batch could be checked in PMD >>>>> stats:: >>>>> >>>>> The average number of packets per output batch can be checked in PMD >>>>> stats:: >>>>> >>>>>> + >>>>>> + $ ovs-appctl dpif-netdev/pmd-stats-show >>>>>> + >>>>>> Limitations >>>>>> ------------ >>>>>> >>>>>> -- >>>>>> 2.7.4 >>>> >>>> >>>> >>>> _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev