Thanks for the review. I agree with your comments. I fixed them and applied this to master.
On Fri, Jan 05, 2018 at 11:21:55AM +0000, Jan Scheurich wrote: > Just one small observation below. Otherwise LGTM. > > I have tested the patch and it worked for all cases. I couldn't test the case > that the switch loses connection to a controller in stand-alone fail mode. > > Acked-by: Jan Scheurich <[email protected]> > Tested-by: Jan Scheurich <[email protected]> > > > -----Original Message----- > > From: Ben Pfaff [mailto:[email protected]] > > Sent: Wednesday, 08 November, 2017 04:04 > > To: [email protected] > > Cc: Ben Pfaff <[email protected]>; Periyasamy Palanisamy > > <[email protected]>; Jan Scheurich > > <[email protected]> > > Subject: [PATCH v2] ofproto: Delete all groups and meters when > > (un)configuring a controller. > > > > Open vSwitch has always deleted all flows from the flow table whenever a > > controller is configured or whenever all the controllers are unconfigured. > > After this commit, OVS additionally deletes all OpenFlow groups and meters. > > > > Suggested-by: Periyasamy Palanisamy <[email protected]> > > Suggested-by: Jan Scheurich <[email protected]> > > Signed-off-by: Ben Pfaff <[email protected]> > > --- > > v1->v2: Clear the meter table too (thanks Jan). > > > > AUTHORS.rst | 1 + > > NEWS | 3 +++ > > ofproto/ofproto.c | 26 +++++++++++++++++------ > > tests/ofproto.at | 58 > > ++++++++++++++++++++++++++++++++++++++++++++++++++++ > > vswitchd/vswitch.xml | 15 +++++++------- > > 5 files changed, 90 insertions(+), 13 deletions(-) > > > > diff --git a/AUTHORS.rst b/AUTHORS.rst > > index 139e99b330d8..26f81508d3d5 100644 > > --- a/AUTHORS.rst > > +++ b/AUTHORS.rst > > @@ -519,6 +519,7 @@ Pasi Kärkkäinen [email protected] > > Patrik Andersson R [email protected] > > Paulo Cravero [email protected] > > Pawan Shukla [email protected] > > +Periyasamy Palanisamy [email protected] > > Peter Amidon [email protected] > > Peter Balland [email protected] > > Peter Phaal [email protected] > > diff --git a/NEWS b/NEWS > > index 047f34b9f402..7ef4d6728d28 100644 > > --- a/NEWS > > +++ b/NEWS > > @@ -1,5 +1,8 @@ > > Post-v2.8.0 > > -------------------- > > + - ovs-vswitchd: > > + * Configuring a controller, or unconfiguring all controllers, now > > deletes > > + all groups and meters (as well as all flows). > > - OVN: > > * The "requested-chassis" option for a logical switch port now > > accepts a > > chassis "hostname" in addition to a chassis "name". > > diff --git a/ofproto/ofproto.c b/ofproto/ofproto.c > > index 82c2bb27d348..e762888b746e 100644 > > --- a/ofproto/ofproto.c > > +++ b/ofproto/ofproto.c > > @@ -251,6 +251,8 @@ static void delete_flows__(struct rule_collection *, > > const struct openflow_mod_requester *) > > OVS_REQUIRES(ofproto_mutex); > > > > +static void ofproto_group_delete_all__(struct ofproto *) > > + OVS_REQUIRES(ofproto_mutex); > > static bool ofproto_group_exists(const struct ofproto *, uint32_t > > group_id); > > static void handle_openflow(struct ofconn *, const struct ofpbuf *); > > static enum ofperr ofproto_flow_mod_init(struct ofproto *, > > @@ -1566,6 +1568,8 @@ ofproto_flush__(struct ofproto *ofproto) > > } > > delete_flows__(&rules, OFPRR_DELETE, NULL); > > } > > + ofproto_group_delete_all__(ofproto); > > + meter_delete_all(ofproto); > > When the ofproto instance is destroyed meter_delete_all() appears to be now > invoked twice: > first from ofproto_destroy() directly and then a second time from here. It > doesn't seem to do any harm, > but I guess it would be cleaner to remove the meter_delete_all() call from > ofproto_destroy(). > > It seems that the hmap_destroy(&p->meters) call in ofproto_destroy() should > also better be moved to the rcu-deferred ofproto_destroy__() function. > > > /* XXX: Concurrent handler threads may insert new learned flows based > > on > > * learn actions of the now deleted flows right after we release > > * 'ofproto_mutex'. */ > > @@ -7348,20 +7352,30 @@ ofproto_group_mod_finish(struct ofproto *ofproto, > > * > > * This is intended for use within an ofproto provider's 'destruct' > > * function. */ > > -void > > -ofproto_group_delete_all(struct ofproto *ofproto) > > - OVS_EXCLUDED(ofproto_mutex) > > +static void > > +ofproto_group_delete_all__(struct ofproto *ofproto) > > + OVS_REQUIRES(ofproto_mutex) > > { > > struct ofproto_group_mod ogm; > > - > > ogm.gm.command = OFPGC11_DELETE; > > ogm.gm.group_id = OFPG_ALL; > > - > > - ovs_mutex_lock(&ofproto_mutex); > > ogm.version = ofproto->tables_version + 1; > > + > > ofproto_group_mod_start(ofproto, &ogm); > > ofproto_bump_tables_version(ofproto); > > ofproto_group_mod_finish(ofproto, &ogm, NULL); > > +} > > + > > +/* Delete all groups from 'ofproto'. > > + * > > + * This is intended for use within an ofproto provider's 'destruct' > > + * function. */ > > +void > > +ofproto_group_delete_all(struct ofproto *ofproto) > > + OVS_EXCLUDED(ofproto_mutex) > > +{ > > + ovs_mutex_lock(&ofproto_mutex); > > + ofproto_group_delete_all__(ofproto); > > ovs_mutex_unlock(&ofproto_mutex); > > } > > > > diff --git a/tests/ofproto.at b/tests/ofproto.at > > index 31cb5208fc1c..f51fd7e97859 100644 > > --- a/tests/ofproto.at > > +++ b/tests/ofproto.at > > @@ -6023,3 +6023,61 @@ OVS_VSWITCHD_STOP(["/NXFMFC_INVALID_TLV_FIELD/d > > /tun_metadata0/d > > /OFPBAC_BAD_SET_LEN/d"]) > > AT_CLEANUP > > + > > +AT_SETUP([ofproto - flush flows, groups, and meters for controller change]) > > +AT_KEYWORDS([flow flows group group meter]) > > +OVS_VSWITCHD_START > > + > > +add_flow_group_and_meter () { > > + AT_CHECK([ovs-ofctl add-flow br0 in_port=1,actions=2]) > > + AT_CHECK([ovs-ofctl -O OpenFlow11 add-group br0 > > group_id=1234,type=all,bucket=output:10 > > + AT_CHECK([ovs-ofctl -O OpenFlow13 add-meter br0 'meter=1 pktps burst > > stats bands=type=drop rate=1 burst_size=1']) > > +]) > > +} > > + > > +verify_added () { > > + AT_CHECK([ovs-ofctl --no-stats dump-flows br0], [0], [dnl > > + in_port=1 actions=output:2 > > +]) > > + AT_CHECK([ovs-ofctl -O OpenFlow11 dump-groups br0], [0], [dnl > > +OFPST_GROUP_DESC reply (OF1.1) (xid=0x2): > > + group_id=1234,type=all,bucket=actions=output:10 > > +]) > > + AT_CHECK([ovs-ofctl -O OpenFlow13 dump-meters br0], [0], [dnl > > +OFPST_METER_CONFIG reply (OF1.3) (xid=0x2): > > +meter=1 pktps burst stats bands= > > +type=drop rate=1 burst_size=1 > > +]) > > +} > > + > > +verify_deleted () { > > + AT_CHECK([ovs-ofctl --no-stats dump-flows br0]) > > + AT_CHECK([ovs-ofctl -O OpenFlow11 dump-groups br0], [0], [dnl > > +OFPST_GROUP_DESC reply (OF1.1) (xid=0x2): > > +]) > > + AT_CHECK([ovs-ofctl -O OpenFlow13 dump-meters br0], [0], [dnl > > +OFPST_METER_CONFIG reply (OF1.3) (xid=0x2): > > +]) > > +} > > + > > +# Add flow, group, meter and check that they're there, without a > > controller. > > +add_flow_group_and_meter > > +verify_added > > + > > +# Set up a controller and verify that the flow and group were deleted, > > +# then add them back. > > +AT_CHECK([ovs-vsctl set-controller br0 'tcp:<invalid>:6653']) > > +verify_deleted > > +add_flow_group_and_meter > > +verify_added > > + > > +# Change the conroller and verify that the flow and group are still there. > > +AT_CHECK([ovs-vsctl set-controller br0 'tcp:<invalid2>:6653']) > > +verify_added > > + > > +# Clear the controller and verify that the flow and group were deleted. > > +AT_CHECK([ovs-vsctl del-controller br0]) > > +verify_deleted > > + > > +OVS_VSWITCHD_STOP(["/<invalid/d"]) > > +AT_CLEANUP > > diff --git a/vswitchd/vswitch.xml b/vswitchd/vswitch.xml > > index d7f68393b25e..a12ec0f81545 100644 > > --- a/vswitchd/vswitch.xml > > +++ b/vswitchd/vswitch.xml > > @@ -751,12 +751,12 @@ > > > > <p> > > If there are primary controllers, removing all of them clears the > > - flow table. If there are no primary controllers, adding one also > > - clears the flow table. Other changes to the set of controllers, > > such > > - as adding or removing a service controller, adding another > > primary > > - controller to supplement an existing primary controller, or > > removing > > - only one of two primary controllers, have no effect on the flow > > - table. > > + OpenFlow flow tables, group table, and meter table. If there > > are no > > + primary controllers, adding one also clears these tables. Other > > + changes to the set of controllers, such as adding or removing a > > + service controller, adding another primary controller to > > supplement > > + an existing primary controller, or removing only one of two > > primary > > + controllers, have no effect on these tables. > > </p> > > </column> > > > > @@ -806,7 +806,8 @@ > > configured controllers can be contacted.</p> > > <p> > > Changing <ref column="fail_mode"/> when no primary controllers > > are > > - configured clears the flow table. > > + configured clears the OpenFlow flow tables, group table, and > > meter > > + table. > > </p> > > </column> > > > > -- > > 2.10.2 > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev