On Mon, Mar 19, 2018 at 12:52 PM, <[email protected]> wrote: > > From: Numan Siddique <[email protected]> > > ovn-controller is not considering Port_Binding option "requested-chassis" > when adding flows in table 0 and table 65. This patch adds this check.
Hi Numan, The check looks good, but sorry that I didn't understand the problem. E.g. there are 2 host A and B, and lsp1 is set as iface-id on both hosts. When requested-chassis for lsp1 is A, then in SB DB the port-binding should be on A. Then in physical.c when processing the port binding for lsp1, it should always point to host A. So how could the VIF on B be reachable? Could you help explain a little bit? Thanks, Han > > Reported-by: Marcin Mirecki <[email protected]> > Reported-at: https://mail.openvswitch.org/pipermail/ovs-dev/2018-March/345266.html > > Signed-off-by: Numan Siddique <[email protected]> > --- > ovn/controller/physical.c | 11 +++++++++++ > tests/ovn.at | 32 +++++++++++++++++++++++++++----- > 2 files changed, 38 insertions(+), 5 deletions(-) > > diff --git a/ovn/controller/physical.c b/ovn/controller/physical.c > index 5a80e2cda..84113ebd2 100644 > --- a/ovn/controller/physical.c > +++ b/ovn/controller/physical.c > @@ -466,6 +466,17 @@ consider_port_binding(struct controller_ctx *ctx, > } else { > ofport = u16_to_ofp(simap_get(&localvif_to_ofport, > binding->logical_port)); > + const char *requested_chassis = smap_get(&binding->options, > + "requested-chassis"); > + if (ofport && requested_chassis && > + strcmp(requested_chassis, chassis->name) && > + strcmp(requested_chassis, chassis->hostname)) { > + /* Even though there is an ofport for this port_binding, it is > + * requested on a different chassis. So ignore this ofport. > + */ > + ofport = 0; > + } > + > if ((!strcmp(binding->type, "localnet") > || !strcmp(binding->type, "l2gateway")) > && ofport && binding->tag) { > diff --git a/tests/ovn.at b/tests/ovn.at > index 5f985f345..75b32ef1a 100644 > --- a/tests/ovn.at > +++ b/tests/ovn.at > @@ -9112,13 +9112,15 @@ sim_add hv1 > as hv1 > ovs-vsctl add-br br-phys > ovn_attach n1 br-phys 192.168.0.11 > -ovs-vsctl -- add-port br-int hv1-vif0 > +ovs-vsctl -- add-port br-int hv1-vif0 -- \ > +set Interface hv1-vif0 ofport-request=1 > > sim_add hv2 > as hv2 > ovs-vsctl add-br br-phys > ovn_attach n1 br-phys 192.168.0.12 > -ovs-vsctl -- add-port br-int hv2-vif0 > +ovs-vsctl -- add-port br-int hv2-vif0 -- \ > +set Interface hv2-vif0 ofport-request=1 > > # Allow only chassis hv1 to bind logical port lsp0. > ovn-nbctl lsp-set-options lsp0 requested-chassis=hv1 > @@ -9138,7 +9140,11 @@ ovs-vsctl set interface hv2-vif0 external-ids:iface-id=lsp0 > OVS_WAIT_UNTIL([test 1 = $(grep -c "Not claiming lport lsp0" hv2/ovn-controller.log)]) > AT_CHECK([test x$(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = x], [0], []) > > -# (2) Chassis hv1 should bind lsp0 when physical to logical mapping exists on hv1. > +# (2) Chassis hv2 should not add flows in OFTABLE_PHY_TO_LOG and OFTABLE_LOG_TO_PHY tables. > +AT_CHECK([as hv2 ovs-ofctl dump-flows br-int table=0 | grep in_port=1], [1], []) > +AT_CHECK([as hv2 ovs-ofctl dump-flows br-int table=65 | grep output], [1], []) > + > +# (3) Chassis hv1 should bind lsp0 when physical to logical mapping exists on hv1. > echo "verifying that hv1 binds lsp0 when hv1 physical/logical mapping is added" > as hv1 > ovs-vsctl set interface hv1-vif0 external-ids:iface-id=lsp0 > @@ -9146,7 +9152,12 @@ ovs-vsctl set interface hv1-vif0 external-ids:iface-id=lsp0 > OVS_WAIT_UNTIL([test 1 = $(grep -c "Claiming lport lsp0" hv1/ovn-controller.log)]) > AT_CHECK([test $(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = "$hv1_uuid"], [0], []) > > -# (3) Chassis hv1 should release lsp0 binding and chassis hv2 should bind lsp0 when > +# (4) Chassis hv1 should add flows in OFTABLE_PHY_TO_LOG and OFTABLE_LOG_TO_PHY tables. > +as hv1 ovs-ofctl dump-flows br-int > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=0 | grep in_port=1], [0], [ignore]) > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=65 | grep actions=output:1], [0], [ignore]) > + > +# (5) Chassis hv1 should release lsp0 binding and chassis hv2 should bind lsp0 when > # the requested chassis for lsp0 is changed from hv1 to hv2. > echo "verifying that lsp0 binding moves when requested-chassis is changed" > > @@ -9154,6 +9165,13 @@ ovn-nbctl lsp-set-options lsp0 requested-chassis=hv2 > OVS_WAIT_UNTIL([test 1 = $(grep -c "Releasing lport lsp0 from this chassis" hv1/ovn-controller.log)]) > OVS_WAIT_UNTIL([test $(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = "$hv2_uuid"]) > > +# (6) Chassis hv2 should add flows and hv1 should not. > +AT_CHECK([as hv2 ovs-ofctl dump-flows br-int table=0 | grep in_port=1], [0], [ignore]) > +AT_CHECK([as hv2 ovs-ofctl dump-flows br-int table=65 | grep actions=output:1], [0], [ignore]) > + > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=0 | grep in_port=1], [1], []) > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=65 | grep output], [1], []) > + > OVN_CLEANUP([hv1],[hv2]) > > AT_CLEANUP > @@ -9170,7 +9188,7 @@ sim_add hv1 > as hv1 > ovs-vsctl add-br br-phys > ovn_attach n1 br-phys 192.168.0.11 > -ovs-vsctl -- add-port br-int hv1-vif0 > +ovs-vsctl -- add-port br-int hv1-vif0 -- set Interface hv1-vif0 ofport-request=1 > > hv1_hostname=$(ovn-sbctl --bare --columns hostname find Chassis name=hv1) > echo "hv1_hostname=${hv1_hostname}" > @@ -9181,11 +9199,15 @@ hv1_uuid=$(ovn-sbctl --bare --columns _uuid find Chassis name=hv1) > echo "hv1_uuid=${hv1_uuid}" > OVS_WAIT_UNTIL([test 1 = $(grep -c "Claiming lport lsp0" hv1/ovn-controller.log)]) > AT_CHECK([test x$(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = x"$hv1_uuid"], [0], []) > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=0 | grep in_port=1], [0], [ignore]) > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=65 | grep actions=output:1], [0], [ignore]) > > ovn-nbctl --wait=hv --timeout=3 lsp-set-options lsp0 requested-chassis=non-existant-chassis > OVS_WAIT_UNTIL([test 1 = $(grep -c "Releasing lport lsp0 from this chassis" hv1/ovn-controller.log)]) > ovn-nbctl --wait=hv --timeout=3 sync > AT_CHECK([test x$(ovn-sbctl --bare --columns chassis find port_binding logical_port=lsp0) = x], [0], []) > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=0 | grep in_port=1], [1], []) > +AT_CHECK([as hv1 ovs-ofctl dump-flows br-int table=65 | grep output], [1], []) > > OVN_CLEANUP([hv1]) > > -- > 2.14.3 > > _______________________________________________ > dev mailing list > [email protected] > https://mail.openvswitch.org/mailman/listinfo/ovs-dev _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev