On Sat, May 19, 2018 at 02:25:05PM -0700, Han Zhou wrote:
> ovn-controller abort was found in pinctrl_run() when debugging
> an occasional test case failure of:
>     ovn-controller.at: Chassis external-id

Thanks a lot.  I think I understand the problem now.

I think that the approach that this patch takes is a bit difficult to
maintain because it relies on every bit of code that needs to send a
message checking the OpenFlow version, even if it's been checked earlier
that the connection is up.

I sent a patch for another approach that seems to me to be easier to
maintain:
https://patchwork.ozlabs.org/patch/919461/
What do you think?
_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev